Urinary proteome profiling using microfluidic technology on a chip

被引:37
作者
Thongboonkerd, Visith [1 ]
Songtawee, Napat
Sritippayawan, Suchai
机构
[1] Mahidol Univ, Siriraj Hosp, Med Mol Biol Unit, Off Res & Dev, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Div Nephrol, Dept Med, Bangkok 10700, Thailand
关键词
proteomics; proteome; urine; microfluidics; chip; arrays; diagnostics; biomarker discovery;
D O I
10.1021/pr060586+
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Clinical diagnostics and biomarker discovery are the major focuses of current clinical proteomics. In the present study, we applied microfluidic technology on a chip for proteome profiling of human urine from 31 normal healthy individuals (15 males and 16 females), 6 patients with diabetic nephropathy (DN), and 4 patients with IgA nephropathy (IgAN). Using only 4 mu L of untreated urine, automated separation of proteins/peptides was achieved, and 1-7 (3.8 +/- 0.3) spectra/bands of urinary proteins/peptides were observed in the normal urine, whereas 8-16 (11.3 +/- 1.2) and 9-14 (10.8 +/- 1.2) spectra were observed in urine samples of DN and IgAN, respectively. Coefficient of variations of amplitudes of lower marker (1.2 kDa), system spectra (6-8 kDa), and upper marker (260.0 kDa) were 22.84, 24.92, and 32.65%, respectively. ANOVA with Tukey post-hoc multiple comparisons revealed 9 spectra of which amplitudes significantly differed between normal and DN urine (DN/normal amplitude ratios ranged from 2.9 to 3102.7). Moreover, the results also showed that 3 spectra (with molecular masses of 12-15, 27-28, and 34-35 kDa) were significantly different between DN and IgAN urine (DN/IgAN amplitude ratios ranged from 3.9 to 7.4). In addition to the spectral amplitudes, frequencies of some spectra could differentiate the normal from the diseased urine but could not distinguish between DN and IgAN. There was no significant difference, regarding the spectral amplitude or frequency, observed between males and females. These data indicate that the microfluidic chip technology is applicable for urinary proteome profiling with potential uses in clinical diagnostics and biomarker discovery.
引用
收藏
页码:2011 / 2018
页数:8
相关论文
共 27 条
[11]  
Lopez MF, 2000, ELECTROPHORESIS, V21, P3673, DOI 10.1002/1522-2683(200011)21:17<3673::AID-ELPS3673>3.3.CO
[12]  
2-D
[13]   A lab-on-a-chip for spectrophotometric analysis of biological fluids [J].
Minas, G ;
Wolffenbuttel, RF ;
Correia, JH .
LAB ON A CHIP, 2005, 5 (11) :1303-1309
[14]   Microchip-based liquid-liquid extraction for gas-chromatography analysis of amphetamine-type stimulants in urine [J].
Miyaguchi, Hajime ;
Tokeshi, Manabu ;
Kikutani, Yoshikuni ;
Hibara, Akihide ;
Inoue, Hiroyuki ;
Kitamori, Takehiko .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1129 (01) :105-110
[15]  
Rabilloud T, 1999, METH MOL B, V112, P9
[16]   Surface-enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI TOF-MS) and ProteinChip® technology in proteomics research [J].
Seibert, V ;
Wiesner, A ;
Buschmann, T ;
Meuer, J .
PATHOLOGY RESEARCH AND PRACTICE, 2004, 200 (02) :83-94
[17]   An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids [J].
Srinivasan, V ;
Pamula, VK ;
Fair, RB .
LAB ON A CHIP, 2004, 4 (04) :310-315
[18]   Current developments in SELDI affinity technology [J].
Tang, N ;
Tornatore, P ;
Weinberger, SR .
MASS SPECTROMETRY REVIEWS, 2004, 23 (01) :34-44
[19]   Renal and urinary proteomics: Current applications and challenges [J].
Thongboonkerd, V ;
Malasit, P .
PROTEOMICS, 2005, 5 (04) :1033-1042
[20]   Proteomics in nephrology: Current status and future directions [J].
Thongboonkerd, V .
AMERICAN JOURNAL OF NEPHROLOGY, 2004, 24 (03) :360-378