Counter-current chromatography separation scaled up from an analytical column to a production column

被引:60
作者
Wood, Philip [1 ]
Ignatova, Svetlana
Janaway, Lee
Keay, David
Hawes, David
Garrard, Ian
Sutherland, Ian A.
机构
[1] Brunel Univ, Brunel Inst Bioengn, Uxbridge UB8 3PH, Middx, England
[2] Dynam Extract Ltd, Slough SL1 4LP, Berks, England
基金
英国生物技术与生命科学研究理事会;
关键词
counter-current chromatography; scale up; mass transfer; high-performance liquid chromatography; high-performance counter-current chromatography;
D O I
10.1016/j.chroma.2007.02.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical separation was performed on an analytical J-type counter-current chromatography (CCC) instrument using a 5.4 ml column, with a 1 ml/min mobile phase flow rate. This separation had a resolution of 0.69 and was achieved in 10 min. The same separation was performed using two 2300 ml columns connected in series at a flow rate of 850 ml/min using a production scale J-type centrifuge. This production scale separation was also obtained in 10 min with a resolution of 0.71. This represents an 850 times increase in productivity. This paper presents these separations and the underlying scale up theory. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 11 条
[1]  
Bird R., 1960, TRANSPORT PHENOMENA, P656
[2]  
Conway WD., 1990, COUNTERCURRENT CHROM
[3]   Separation of epigallocatechin gallate and gallocatechin gallate using multiple instruments connected in series [J].
Du, QZ ;
Ke, CQ ;
Ito, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (1-2) :203-208
[4]   Relationship between the flow-rate of the mobile phase and retention of the stationary phase in counter-current chromatography [J].
Du, QZ ;
Wu, CJ ;
Qian, GJ ;
Wu, PD ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :231-235
[5]   Feasibility of scaling from pilot to process scale [J].
Ignatova, Svetlana ;
Wood, Philip ;
Hawes, David ;
Janaway, Lee ;
Keay, David ;
Sutherland, Ian .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1151 (1-2) :20-24
[6]   A new small coil-volume CCC instrument for direct interfacing with MS [J].
Janaway, L ;
Hawes, D ;
Ignatova, S ;
Wood, P ;
Sutherland, IA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1345-1354
[7]   A new hypothesis on phase distribution in countercurrent chromatography [J].
Sutherland, IA ;
Muytjens, J ;
Prins, M ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (15) :2259-2276
[8]   Modelling CCC using an eluting countercurrent distribution model [J].
Sutherland, IA ;
de Folter, J ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1449-1474
[9]   Industrial scale-up of countercurrent chromatography: Predictive scale-up [J].
Sutherland, IA ;
Brown, L ;
Graham, AS ;
Guillon, GG ;
Hawes, D ;
Janaway, L ;
Whiteside, R ;
Wood, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (01) :21-28
[10]   Stationary phase retention in CCC: Modelling the J-type centrifuge as a constant pressure drop pump [J].
Wood, PL ;
Hawes, D ;
Janaway, L ;
Sutherland, IA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1373-1396