Validation of the transfer function technique for generating central from peripheral upper limb pressure waveform

被引:177
作者
Gallagher, D
Adji, A
O'Rourke, MF
机构
[1] Univ New S Wales, St Vincents Clin, Darlinghurst, NSW 2010, Australia
[2] Univ New S Wales, St Vincents Hosp, Darlinghurst, NSW 2010, Australia
关键词
transfer function; central pressure waveform; arterial tonometry; wave reflection; arterial stiffness;
D O I
10.1016/j.amjhyper.2004.05.027
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Central aortic pressure waveforms can be calculated from the radial artery pressure waveform using a generalized transfer function to correct for pressure wave distortion in the upper limb. Although validated to standards conventionally applied, reservations are still expressed on use of this process, because of the relatively small number of patients from whom appropriate invasive data were obtained. The study described here supplemented such data with noninvasive data obtained from carotid and radial artery tonometry in 439 patients and normal subjects. The carotid-radial artery transfer function was similar to the aortic-radial when allowance was made for wave travel from aorta to carotid artery. The carotid-radial transfer function was identical in male and female individuals, was similar at different arterial pressures and in mature adults. Differences are relatively small, are seen at frequencies where central pressure wave components are small and are similar to those seen with vasodilator agents in invasive studies. Findings provide further support for use of a generalized transfer function to calculate aortic from upper limb pressure and conform with previously established views on vascular impedance. (C) 2004 American Journal of Hypertension, Ltd.
引用
收藏
页码:1059 / 1067
页数:9
相关论文
共 58 条
[51]   Clinical utility of aortic pulses and pressures calculated from applanated radial-artery pulses [J].
Smulyan, H ;
Siddiqui, DS ;
Carlson, RJ ;
London, GM ;
Safar, ME .
HYPERTENSION, 2003, 42 (02) :150-155
[52]   Can a clinically useful aortic pressure wave be derived from a radial pressure wave? [J].
Söderström, S ;
Nyberg, G ;
O'Rourke, MF ;
Sellgren, J ;
Pontén, J .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (04) :481-488
[53]   INPUT IMPEDANCE OF AN ASSEMBLY OF RANDOMLY BRANCHING ELASTIC TUBES [J].
TAYLOR, MG .
BIOPHYSICAL JOURNAL, 1966, 6 (01) :29-&
[55]   Inflection point of ascending aortic waveform is a powerful predictor of restenosis after percutaneous transluminal coronary angioplasty [J].
Ueda, H ;
Nakayama, Y ;
Tsumura, K ;
Yoshimaru, K ;
Hayashi, T ;
Yoshikawa, J .
AMERICAN JOURNAL OF HYPERTENSION, 2002, 15 (09) :823-826
[56]   Carotid pressure is a better predictor of coronary artery disease severity than brachial pressure [J].
Waddell, TK ;
Dart, AM ;
Medley, TL ;
Cameron, JD ;
Kingwell, BA .
HYPERTENSION, 2001, 38 (04) :927-931
[57]   Arterial stiffness, wave reflections, and the risk of coronary artery disease [J].
Weber, T ;
Auer, J ;
O'Rourke, MF ;
Kvas, E ;
Lassnig, E ;
Berent, R ;
Eber, B .
CIRCULATION, 2004, 109 (02) :184-189
[58]  
WOMERSLEY JR, 1957, 56614 WADETR