High-sensitivity miniaturized immunoassays for tumor necrosis factor a using microfluidic systems

被引:158
作者
Cesaro-Tadic, S
Dernick, G
Juncker, D
Buurman, G
Kropshofer, H
Michel, B
Fattinger, C
Delamarche, E
机构
[1] IBM Res GmbH, Zurich Res Lab, CH-8803 Ruschlikon, Switzerland
[2] F Hoffmann La Roche & Cie AG, Pharmaceut Res, CH-4070 Basel, Switzerland
关键词
D O I
10.1039/b408964b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We use microfluidic chips to detect the biologically important cytokine tumor necrosis factor alpha (TNF-alpha) with picomolar sensitivity using sub-microliter volumes of samples and reagents. The chips comprise a number of independent capillary systems (CSs), each of which is composed of a filling port, an appended microchannel, and a capillary pump. Each CS fills spontaneously by capillary forces and includes a self-regulating mechanism that prevents adventitious drainage of the microchannels. Thus, interactive control of the flow in each CS is easily achieved via collective control of the evaporation in all CSs by means of two Peltier elements that can independently heat and cool. Long incubation times are crucial for high sensitivity assays and can be conveniently obtained by adjusting the evaporation rate to have low flow rates of similar to30 nL min(-1). The assay is a sandwich fluorescence immunoassay and takes place on the surface of a poly( dimethylsiloxane) ( PDMS) slab placed across the microchannels. We precoat PDMS with capture antibodies (Abs), localize the capture of analyte molecules using a chip, then bind the captured analyte molecules with fluorescently-tagged detection Abs using a second chip. The assay results in a mosaic of fluorescence signals on the PDMS surface which are measured using a fluorescence scanner. We show that PDMS is a compatible material for high sensitivity fluorescence assays, provided that detection antibodies with long excitation wavelength fluorophores (greater than or equal to580 nm) are employed. The chip design, long incubation times, proper choice of fluorophores, and optimization of the detection Ab concentration all combine to achieve high-sensitivity assays. This is exemplified by an experiment with 170 assay sites, occupying an area of similar to0.6 mm(2) on PDMS to detect TNF-alpha in 600 nL of a dendritic cell (DC) culture medium with a sensitivity of similar to20 pg mL(-1) (1.14 pM).
引用
收藏
页码:563 / 569
页数:7
相关论文
共 36 条
  • [21] MICROFABRICATED CHEMICAL MEASUREMENT SYSTEMS
    RAMSEY, JM
    JACOBSON, SC
    KNAPP, MR
    [J]. NATURE MEDICINE, 1995, 1 (10) : 1093 - 1096
  • [22] Micro total analysis systems. 1. Introduction, theory, and technology
    Reyes, DR
    Iossifidis, D
    Auroux, PA
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2623 - 2636
  • [23] An array immunosensor for simultaneous detection of clinical analytes
    Rowe, CA
    Scruggs, SB
    Feldstein, MJ
    Golden, JP
    Ligler, FS
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (02) : 433 - 439
  • [24] Efficient Presentation of Soluble Antigen by Cultured Human Dendritic Cells Is Maintained by Granulocyte/Macrophage Colony-stimulating Factor Plus Interleukin 4 and Downregulated by Tumor Necrosis Factor α
    Sallusto, Federica
    Lanzavecchia, Antonio
    [J]. JOURNAL OF IMMUNOLOGY, 2018, 200 (03) : 887 - 896
  • [25] Characterization of noncovalent complexes of recombinant human monoclonal antibody and antigen using cation exchange, size exclusion chromatography, and BIAcore
    Santora, LC
    Kaymakcalan, Z
    Sakorafas, P
    Krull, IS
    Grant, K
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 299 (02) : 119 - 129
  • [26] An integrated approach to a portable and low-cost immunoassay for resource-poor settings
    Sia, SK
    Linder, V
    Parviz, BA
    Siegel, A
    Whitesides, GM
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (04) : 498 - 502
  • [27] SOINI E, 1983, CLIN CHEM, V29, P65
  • [28] Nine-analyte detection using an array-based biosensor
    Taitt, CR
    Anderson, GP
    Lingerfelt, BM
    Feldstein, MJ
    Ligler, FS
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (23) : 6114 - 6120
  • [29] Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
    Tüdos, AJ
    Besselink, GAJ
    Schasfoort, RBM
    [J]. LAB ON A CHIP, 2001, 1 (02) : 83 - 95
  • [30] Microfluidics meets MEMS
    Verpoorte, E
    De Rooij, NF
    [J]. PROCEEDINGS OF THE IEEE, 2003, 91 (06) : 930 - 953