Methodological aspects of glucose monitoring with a slow continuous subcutaneous and intravenous ultrafiltration system in rats

被引:24
作者
Kaptein, WA
Kemper, RHA
Ruiters, MHJ
Venema, K
Tiessen, RG
Korf, J
机构
[1] Univ Groningen, Biomed Technol Ctr, NL-9713 EZ Groningen, Netherlands
[2] Acad Hosp, NL-9713 EZ Groningen, Netherlands
关键词
ultrafiltration; biosensor; glucose; venous probe; subcutaneous probe;
D O I
10.1016/S0956-5663(97)00052-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A method for the continuous ultrafiltration of venous blood or subcutaneous fluid is demonstrated with glucose monitoring in the living rat. Ultrafiltrate was withdrawn at a constant flow rate of approximately 100 nl/min. Glucose content of the ultrafiltrates was electrochemically determined with a flow injection analysis method and a bi-enzyme reactor. After glucose loading, the time course of glucose in the ultrafiltrate from the jugular vein was virtually identical, whereas that from the subcutaneous compartment was attenuated and the peaks blunted as compared to glucose levels in concomitantly assayed arterial blood. Our study demonstrates the potential of low rate ultrafiltration for monitoring metabolism with biosensor technology in vivo. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:967 / 976
页数:10
相关论文
共 21 条
[1]  
Ash S R, 1992, ASAIO J, V38, pM416, DOI 10.1097/00002480-199207000-00067
[2]  
Ash S R, 1993, ASAIO J, V39, pM699
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[5]   IN-VIVO MONITORING OF LACTATE AND GLUCOSE WITH MICRODIALYSIS AND ENZYME REACTORS IN INTENSIVE-CARE MEDICINE [J].
DEBOER, J ;
KORF, J ;
PLIJTERGROENDIJK, H .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (03) :163-170
[6]   BIENZYME REACTOR FOR ELECTROCHEMICAL DETECTION OF LOW CONCENTRATIONS OF URIC-ACID AND GLUCOSE [J].
ELEKES, O ;
MOSCONE, D ;
VENEMA, K ;
KORF, J .
CLINICA CHIMICA ACTA, 1995, 239 (02) :153-165
[7]   CLINICAL USEFULNESS OF THE GLUCOSE-CONCENTRATION IN THE SUBCUTANEOUS TISSUE - PROPERTIES AND PITFALLS OF ELECTROCHEMICAL BIOSENSORS [J].
FISCHER, U ;
REBRIN, K ;
VONWOEDTKE, T ;
ABEL, P .
HORMONE AND METABOLIC RESEARCH, 1994, 26 (11) :515-522
[8]   IMPLANTABLE ELECTROCATALYTIC GLUCOSE SENSOR [J].
LAGER, W ;
VONLUCADOU, I ;
NISCHIK, H ;
NOWAK, T ;
PREIDEL, W ;
RUPRECHT, L ;
STANZEL, MJ ;
TEGEDER, V .
HORMONE AND METABOLIC RESEARCH, 1994, 26 (11) :526-530
[9]   DETERMINATION OF ENDOGENOUS IONS IN INTERCELLULAR FLUID USING CAPILLARY ULTRAFILTRATION AND MICRODIALYSIS PROBES [J].
LINHARES, MC ;
KISSINGER, PT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1121-1127
[10]   PHARMACOKINETIC MONITORING IN SUBCUTANEOUS TISSUE USING INVIVO CAPILLARY ULTRAFILTRATION PROBES [J].
LINHARES, MC ;
KISSINGER, PT .
PHARMACEUTICAL RESEARCH, 1993, 10 (04) :598-602