A cadaveric study to assess the accuracy of computer-assisted surgery in locating the hip center during total knee arthroplasty

被引:13
作者
Picard, Frederic
Leitner, Francois
Gregori, Alberto
Martin, Philippe
机构
[1] Ecole Cent Paris, Hlth & Biotech Dept, Chatenay Malabry, France
[2] Ctr Rech & Dev Informat Aeculap, Le Concorde, Eybens, France
[3] Hairmyres Hosp, Dept Orthopaed, E Kilbride, Lanark, Scotland
[4] Ecole Mines Paris, Ctr Automat & Syst, Paris 06, France
关键词
total knee arthroplasty; computer-assisted surgery; hip center accuracy;
D O I
10.1016/j.arth.2006.04.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computer-assisted technology allows the accurate location of inaccessible landmarks such as the center of the hip in total hip arthroplasty. Using 7 fresh normal cadaveric hips, we conducted 2 studies. The first Study compared iliac (A) vs no iliac (B) tracking. The second study assessed the reliability of the hip center acquisition using the range of hip motion during manipulation. The first study revealed no statistical difference between the 2 techniques A (mean, 0.67; SD, 0.15) and B (mean, 0.66; SD, 0.32) used to locate the center of the hip. In the second study, a range of motion less than 10 degrees negatively affected accuracy. Using this technology, without an iliac tracker, allows accurate and precise determination of the center of the hip.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 23 条
[1]
Common complications of total knee arthroplasty [J].
Ayers, DC ;
Dennis, DA ;
Johanson, NA ;
Pellegrini, VD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (02) :278-311
[2]
The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement [J].
Bankes, MJK ;
Back, DL ;
Cannon, SR ;
Briggs, TWR .
KNEE, 2003, 10 (01) :55-60
[3]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[4]
Rates of revision knee replacement in Ontario, Canada [J].
Coyte, PC ;
Hawker, G ;
Croxford, R ;
Wright, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (06) :773-782
[5]
Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[6]
DELP DL, 1998, CLIN ORTHOP RELAT R, V354, P49
[7]
FENG EL, 1994, CLIN ORTHOP RELAT R, P60
[8]
Total knee arthroplasty implanted with and without kinematic navigation [J].
Hart, R ;
Janecek, M ;
Chaker, A ;
Bucek, P .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) :366-369
[9]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[10]
Jenny JY, 2004, COMPUTER ROBOTIC ASS, P179