Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy)

被引:48
作者
Merwa, R
Hollaus, K
Brandstätter, B
Scharfetter, H
机构
[1] Graz Univ Technol, Inst Biomed Engn, A-8010 Graz, Austria
[2] Graz Univ Technol, Inst Fundamentals & Theory Elect Engn, A-8010 Graz, Austria
[3] Graz Univ Technol, Inst Elect Measurement & Measurement Signal Proc, A-8010 Graz, Austria
关键词
magnetic induction tomography; eddy currents; finite elements; bioimpedance; sensitivity distribution;
D O I
10.1088/0967-3334/24/2/364
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic induction tomography (MIT) is used for reconstructing the changes of the conductivity in a target object using alternating magnetic fields. Applications include, for example, the non-invasive monitoring of oedema in the human brain. A powerful software package has been developed which makes it possible to generate a finite element (FE) model of complex structures and to calculate the eddy currents in the object under investigation. To validate our software a model of a previously published experimental arrangement was generated. The model consists of a coaxial coil system and a conducting sphere which is moved perpendicular to the coil axis (a) in an empty space and (b) in a saline-filled cylindrical tank. The agreement of the measured and simulated data is very good when taking into consideration the systematic measurement errors in case (b). Thus the applicability of the simulation algorithm for two-Compartment systems has been demonstrated even in the case of low conductivities and weak contrast. This can be considered an important step towards the solution of the inverse problem of MIT.
引用
收藏
页码:545 / 554
页数:10
相关论文
共 10 条
[1]   Edge element formulations of eddy current problems [J].
Bíró, O .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1999, 169 (3-4) :391-405
[2]   Magnetic induction tomography [J].
Griffiths, H .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) :1126-1131
[3]   Magnetic induction tomography - A measuring system for biological tissues [J].
Griffiths, H ;
Stewart, WR ;
Gough, W .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :335-345
[4]   Symmetric second order edge elements for triangles and tetrahedra [J].
Kameari, A .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (03) :1394-1397
[5]   Magnetic induction tomography: experimental realization [J].
Korjenevsky, A ;
Cherepenin, V ;
Sapetsky, S .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :89-94
[6]   Progress in realization of magnetic induction tomography [J].
Korjenevsky, AV ;
Cherepenin, VA .
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 :346-352
[7]   ELECTROMAGNETIC IMAGING USING MUTUAL INDUCTANCE TOMOGRAPHY - POTENTIAL FOR PROCESS APPLICATIONS [J].
PEYTON, AJ ;
YU, ZZ ;
ALZEIBAK, S ;
SAUNDERS, NH ;
BORGES, AR .
PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 1995, 12 (02) :68-74
[8]   Sensitivity maps and system requirements for magnetic induction tomography using a planar gradiometer [J].
Rosell, J ;
Casañas, R ;
Scharfetter, H .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :121-130
[9]   Sensitivity maps for low-contrast perturbations within conducting background in magnetic induction tomography [J].
Scharfetter, H ;
Riu, P ;
Populo, M ;
Rosell, J .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) :195-202
[10]   Magnetic induction tomography: hardware for multi-frequency measurements in biological tissues [J].
Scharfetter, H ;
Lackner, HK ;
Rosell, J .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :131-146