Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography

被引:115
作者
Grover, Sandeep [1 ]
Murthy, Ravi K. [1 ]
Brar, Vikram S. [1 ]
Chalam, Kakarla V. [1 ]
机构
[1] Univ Florida, Coll Med, Dept Ophthalmol, Jacksonville, FL 32209 USA
关键词
DIABETIC MACULAR EDEMA; TRIAMCINOLONE;
D O I
10.1167/iovs.09-4774
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Spectral-domain optical coherence tomography (SD-OCT) is an advancement over time-domain OCT (TD-OCT) in the imaging of retinal disorders. Retinal thickness measured by SD-OCT differs from that measured by TD-OCT because the delineation of the outer boundary of the retina differs in the two instruments. The present study aims to evaluate this difference by comparing macular thickness, as obtained by Stratus and Spectralis OCT, in subjects without any known retinal disease. METHODS. Thirty-six subjects with no history of retinal disease and with normal vision and normal intraocular pressure were enrolled in the study. Both Stratus and Spectralis OCT scanning were performed by the same operator on all subjects in one eye. Central point thickness (CPT) and retinal thickness in nine ETDRS subfields, including central subfield (CSF), were measured. Student's t-test was used to determine statistical significance. RESULTS. Mean CPT, as measured by the Stratus and Spectralis OCT, was 166.9 +/- 20.9 mu m and 225.1 +/- 17.1 mu m (P < 0.0001), and mean CSF was 202.3 +/- 19.6 mu m and 271.4 +/- 19.6 mu m (P < 0.0001), respectively. Although the mean difference in CSF thickness was 69.1 mu m, it ranged from 61.9 to 74 mu m in the other eight ETDRS subfields. CONCLUSIONS. An increased measurement in retinal thickness of approximately 65 to 70 mu m, as measured by Spectralis OCT compared with Stratus OCT, is consistent with the extent of axial retinal thickness measured by the two instruments. This increased measurement corresponds to the inclusion of the outer segment-RPE-Bruch's membrane complex by Spectralis OCT, which is relevant to studies using the newer SD-OCT for assessment of retinal thickness. (Invest Ophthalmol Vis Sci. 2010;51:2644-2647) DOI:10.1167/iovs.09-4774
引用
收藏
页码:2644 / 2647
页数:4
相关论文
共 17 条
[1]   Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging [J].
Alam, Suhail ;
Zawadzki, Robert J. ;
Choi, Stacey ;
Gerth, Christina ;
Park, Susanna S. ;
Morse, Lawrence ;
Werner, John S. .
OPHTHALMOLOGY, 2006, 113 (08) :1425-1431
[2]   Ultrahigh resolution optical coherence tomography of the monkey fovea. Identification of retinal sublayers by correlation with semithin histology sections [J].
Anger, EM ;
Unterhuber, A ;
Hermann, B ;
Sattmann, H ;
Schubert, C ;
Morgan, JE ;
Cowey, A ;
Ahnelt, PK ;
Drexler, W .
EXPERIMENTAL EYE RESEARCH, 2004, 78 (06) :1117-1125
[3]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P741
[4]   Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography [J].
Chan, A ;
Duker, JS ;
Ko, TH ;
Fujimoto, JG ;
Schuman, JS .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (02) :193-198
[5]   Randomized trial of peribulbar triamcinolone acetonide with and without focal photocoagulation for mild diabetic macular edema - A pilot study [J].
Chew, E. ;
Strauber, S. ;
Beck, R. ;
Aiello, L. P. ;
Antoszyk, A. ;
Bressler, N. ;
Browning, D. ;
Danis, R. ;
Fan, J. ;
Flaxel, C. ;
Friedman, S. ;
Glassman, A. ;
Kollman, C. ;
Lazarus, H. ;
Patel, S. ;
Callanan, D. ;
Elman, M. ;
Raden, R. ;
Sharuk, G. ;
Arrigg, P. ;
Schlossman, D. ;
Davidorf, F. ;
Chambers, R. ;
Li, H. ;
Drouilhet, J. ;
DiLoreto, D., Jr. ;
Benner, J. ;
Butler, J. ;
Chan, C. ;
Lin, S. ;
Lyon, A. ;
Mathura, J. ;
Ie, D. ;
Lipkowitz, J. ;
Shami, M. ;
Gonzalez, V. ;
Vann, V. ;
Wong, K. ;
Niffenegger, J. ;
Singerman, L. ;
Miller, D. ;
Gross, J. ;
Fishburne, B. ;
Garcia, Charles A. ;
Garcia, C. ;
Foster, W. ;
Baker, C. ;
Goodart, R. ;
Faber, D. ;
Mehr, D. .
OPHTHALMOLOGY, 2007, 114 (06) :1190-1196
[6]   Normative Data for Macular Thickness by High-Definition Spectral-Domain Optical Coherence Tomography (Spectralis) [J].
Grover, Sandeep ;
Murthy, Ravi K. ;
Brar, Vikram S. ;
Chalam, Kakarla V. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) :266-271
[7]   QUANTITATIVE ASSESSMENT OF MACULAR EDEMA WITH OPTICAL COHERENCE TOMOGRAPHY [J].
HEE, MR ;
PULIAFITO, CA ;
WONG, C ;
DUKER, JS ;
REICHEL, E ;
RUTLEDGE, B ;
SCHUMAN, JS ;
SWANSON, EA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (08) :1019-1029
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Comparison of Macular Thickness Between Cirrus HD-OCT and Stratus OCT [J].
Kakinoki, Masashi ;
Sawada, Osamu ;
Sawada, Tomoko ;
Kawamura, Hajime ;
Ohji, Masahito .
OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (02) :135-140
[10]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525