Pushing the Envelope New Computed Tomography Techniques for Cardiothoracic Imaging

被引:57
作者
Flohr, Thomas G. [1 ,2 ]
Klotz, Ernst [1 ]
Allmendinger, Thomas [1 ]
Raupach, Rainer [1 ]
Bruder, Herbert [1 ]
Schmidt, Bernhard [1 ]
机构
[1] Siemens Healthcare, Computed Tomog Div, D-91301 Forchheim, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, D-72074 Tubingen, Germany
关键词
computed tomography; multidetector row computed tomography; dual-source computed tomography; cardiac computed tomography; cardiothoracic computed tomography; computed tomography perfusion; radiation dose; DUAL-SOURCE CT; NONINVASIVE CORONARY-ANGIOGRAPHY; ACUTE PULMONARY-EMBOLISM; MULTIDETECTOR-ROW CT; HEART-RATE; DIAGNOSTIC-ACCURACY; MULTISLICE CT; MYOCARDIAL-PERFUSION; RADIATION-EXPOSURE; PERFORMANCE EVALUATION;
D O I
10.1097/RTI.0b013e3181d7e898
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Multidetector row computed tomography (MDCT) has been used for cardiothoracic imaging since the advent of 4-slice computed tomography (CT) in 1999. Available since 2004, 64-slice CT systems are currently considered a prerequisite for successfully integrating cardiothoracic CT into routine clinical algorithms. Developments are ongoing that aim to solve the remaining challenges of cardiothoracic CT. In this review article, we focus on 3 aspects that have significantly influenced the design of newer CT scanners. (1) A faster scan speed enables coverage of the cardiothoracic anatomy in shorter scan times, which is beneficial for patients with limited ability to cooperate and opens new clinical possibilities. A coveted goal for cardiac CT is a "snapshot image" of the entire heart in 1 cardiac cycle, which can be obtained by using MDCT systems with area detectors or dual-source CT systems with electrocardiogram (ECG)-triggered high-pitch spiral. (2) Techniques to reduce the radiation dose to the patient, such as ECG-controlled dose modulation, ECG-triggered sequential CT, low kV scanning, and iterative reconstruction, have gained considerable attention as a consequence of the ongoing discussion of radiation exposure by CT. (3) New developments aim to establish a role for CT in the functional imaging of the lung and of the heart beyond the mere visualization of anatomy. Evaluation of the first-pass enhancement of the myocardium, with single-energy or with dual-energy data acquisition, and cardiac perfusion examinations may have the potential to enhance the application spectrum of cardiac CT by providing the means to determine the hemodynamic relevance of coronary artery stenosis.
引用
收藏
页码:100 / 111
页数:12
相关论文
共 111 条
[1]
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]
Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[3]
Achenbach S, 2009, EUR HEART J
[4]
Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[5]
Randomized Comparison of 64-Slice Single- and Dual-Source Computed Tomography Coronary Angiography for the Detection of Coronary Artery Disease [J].
Achenbach, Stephan ;
Ropers, Ulrike ;
Kuettner, Axel ;
Anders, Katharina ;
Pflederer, Tobias ;
Komatsu, Sei ;
Bautz, Werner ;
Daniel, Werner G. ;
Ropers, Dieter .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) :177-186
[6]
Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Plass, Andre ;
Genoni, Michele ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) :385-391
[7]
Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques [J].
Arnoldi, Elisabeth ;
Johnson, Thorsten R. ;
Rist, Carsten ;
Wintersperger, Bernd J. ;
Sommer, Wieland H. ;
Becker, Alexander ;
Becker, Christoph R. ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
EUROPEAN RADIOLOGY, 2009, 19 (09) :2147-2155
[8]
Dynamic myocardial stress perfusion imaging using fast dual-source CT with alternating table positions: initial experience [J].
Bamberg, Fabian ;
Klotz, Ernst ;
Flohr, Thomas ;
Becker, Alexander ;
Becker, Christoph R. ;
Schmidt, Bernhard ;
Wintersperger, Bernd J. ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1168-1173
[9]
CT of Coronary Artery Disease [J].
Bastarrika, Gorka ;
Lee, Yeong Shyan ;
Huda, Walter ;
Ruzsics, Balazs ;
Costello, Philip ;
Schoepf, U. Joseph .
RADIOLOGY, 2009, 253 (02) :317-338
[10]
Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :423-424