Real-time magnetic resonance imaging-guided coronary catheterization in swine

被引:48
作者
Omary, RA
Green, JD
Schirf, BE
Li, YZ
Finn, JP
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
magnetic resonance imaging; catheterization; arteries; angiography;
D O I
10.1161/01.CIR.0000074776.88681.F5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - We tested the hypothesis that real-time magnetic resonance imaging (MRI) can guide coronary artery catheterization in swine via a percutaneous femoral artery approach. Methods and Results - In 12 pigs, we accessed femoral arteries percutaneously. We used 6- or 7-French coronary Judkins catheters filled with dilute 4% gadolinium (Gd) contrast agent and coaxially inserted 0.030-inch diameter active guidewires as endovascular devices. For catheter tracking, we used a 2-dimensional (2D) inversion recovery - prepared spoiled gradient echo sequence at a temporal resolution of 7 frames/s. For guidewire tracking, we used 2D steady-state free precession imaging at a temporal resolution of 9 frames/s. Coronary artery catheterization under MRI guidance was successful in 12/12 pigs. Successful coronary catheterization was verified by obtaining MR angiographic images after direct catheter-based injections of dilute Gd. Conclusions - Real-time MRI-guided catheterization of coronary arteries in swine is feasible via a percutaneous femoral artery approach. Selective coronary MR angiography can then be performed with dilute contrast agent injections.
引用
收藏
页码:2656 / 2659
页数:4
相关论文
共 16 条
[11]  
2-3
[12]   Real-time projection MR angiography: Feasibility study [J].
Serfaty, JM ;
Atalar, E ;
Declerck, J ;
Karmakar, P ;
Quick, HH ;
Shunk, KA ;
Heldman, AW ;
Yang, XM .
RADIOLOGY, 2000, 217 (01) :290-295
[13]   Magnetic resonance-guided coronary artery stent placement in a swine model [J].
Spuentrup, E ;
Ruebben, A ;
Schaeffter, T ;
Manning, WJ ;
Günther, RW ;
Buecker, A .
CIRCULATION, 2002, 105 (07) :874-879
[14]   A rapid 2D time-resolved variable-rate k-space sampling MR technique for passive catheter tracking during endovascular procedures [J].
Unal, O ;
Korosec, FR ;
Frayne, R ;
Strother, CM ;
Mistretta, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :356-362
[15]   MR imaging-guided intravascular procedures: Initial demonstration in a pig model [J].
Wildermuth, S ;
Debatin, JF ;
Leung, DA ;
Dumoulin, CL ;
Darrow, RD ;
Uhlschmid, G ;
Hofmann, E ;
Thyregod, J ;
vonSchulthess, GK .
RADIOLOGY, 1997, 202 (02) :578-583
[16]   Intravascular MR-monitored balloon angioplasty: An in vivo feasibility study [J].
Yang, XM ;
Bolster, BD ;
Kraitchman, DL ;
Atalar, E .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (06) :953-959