In vivo MR tractography using diffusion imaging

被引:142
作者
Bammer, R [1 ]
Acar, B [1 ]
Moseley, ME [1 ]
机构
[1] Stanford Univ, Lucas MRS I Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
magnetic resonance imaging; diffusion; tensor; fiber tracking; tractography;
D O I
10.1016/S0720-048X(02)00311-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion in structured tissue, such as white matter or muscle, is anisotropic. MR diffusion tensor imaging (DTI) measures anisotropy per pixel and provides the directional information relevant for MR tractography or fiber tracking in vivo. MR tractography is non-invasive, relatively fast, and can be repeated multiple times without destructing important tissue. Moreover, the combination with other MR images is relatively simple. In this paper, the basic principles of tractography are presented. Different tracking methods with varying degrees of complexity are introduced and their potential strengths and weaknesses are discussed. Clinical applications and different strategies for evaluating the fidelity of tracking results are reviewed. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:223 / 234
页数:12
相关论文
共 60 条
[11]  
BATCHELOR PG, 2002, P INT SOC MAGN RESON, P1135
[12]   Multicomponent water proton transverse relaxation and T2-discriminated water diffusion in myelinated and nonmyelinated nerve [J].
Beaulieu, C ;
Fenrich, FR ;
Allen, PS .
MAGNETIC RESONANCE IMAGING, 1998, 16 (10) :1201-1210
[13]   Tracking neuronal fiber pathways in the living human brain [J].
Conturo, TE ;
Lori, NF ;
Cull, TS ;
Akbudak, E ;
Snyder, AZ ;
Shimony, JS ;
McKinstry, RC ;
Burton, H ;
Raichle, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (18) :10422-10427
[14]  
COULON O, 2001, RN0137 U COLL LOND D
[15]  
COULON O, 2001, P MIUA 01 BRIT C MED
[16]  
Crank J., 1956, The Mathematics of Diffusion
[17]   Validation of diffusion tensor MRI-based muscle fiber tracking [J].
Damon, BM ;
Ding, ZH ;
Anderson, AW ;
Freyer, AS ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :97-104
[18]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[19]   Characterization of anisotropy in high angular resolution diffusion-weighted MRI [J].
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1083-1099
[20]   Anisotropy in high angular resolution diffusion-weighted MRI [J].
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :935-939