Adequate margins for random setup uncertainties in head-and-neck IMRT

被引:112
作者
Astreinidou, E
Bel, A
Raaijmakers, CPJ
Terhaard, CHJ
Lagendijk, JJW
机构
[1] Univ Utrecht, Med Ctr, Dept Radiotherapy, NL-3584 CX Utrecht, Netherlands
[2] Nucletron BV, Veenendaal, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 61卷 / 03期
关键词
IMRT; head and neck; margins; random errors; setup uncertainties;
D O I
10.1016/j.ijrobp.2004.11.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the effect of random setup uncertainties on the highly conformal dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head-and-neck cancer patients and to determine adequate margins to account for those uncertainties. Methods and Materials: We have implemented in our clinical treatment planning system the possibility of simulating normally distributed patient setup displacements, translations, and rotations. The planning CT data of 8 patients with Stage TI-T3NOMO oropharyngeal cancer were used. The clinical target volumes of the primary tumor (CTVPprimary) and of the lymph nodes (CTVelective) were expanded by 0.0, 1.5, 3.0, and 5.0 min in all directions, creating the planning target volumes (PTVs). We performed IMRT dose calculation using our class solution for each PTV margin, resulting in the conventional static plans. Then, the system recalculated the plan for each positioning displacement derived from a normal distribution with sigma = 2 min and sigma = 4 min (standard deviation) for translational deviations and sigma = 1degrees for rotational deviations. The dose distributions of the 30 fractions were summed, resulting in the actual plan. The CTV dose coverage of the actual plans was compared with that of the static plans. Results: Random translational deviations of or = 2 mm and rotational deviations of sigma = 1degrees did not affect the CTVprimary volume receiving 95% of the prescribed dose (V,,) regardless of the PTV margin used. A V,, reduction of 3% and 1% for a 0.0-mm and 1.5-mm PTV margin, respectively, was observed for or = 4 mm. The V-95 of the CTVelective contralateral was approximately 1% and 5% lower than that of the static plan for sigma = 2 min and or = 4 mm, respectively, and for PTV margins < 5.0 mm. An additional reduction of 1% was observed when rotational deviations were included. The same effect was observed for the CTVelective ipsilateral but with smaller dose differences than those for the contralateral side. The effect of the random uncertainties on the mean dose to the parotid glands was not significant. The maximal dose to the spinal cord increased by a maximum of 3 Gy. Conclusions: The margins to account for random setup uncertainties, in our clinical IMRT solution, should be 1.5 mm and 3.0 mm in the case of sigma = 2 mm and sigma = 4 mm, respectively, for the CTVprimary. Larger margins (5.0 mm), however, should be applied to the CTV.,,,ti,., if the goal of treatment is a V,, value of at least 99%. (C) 2005 Elsevier Inc.
引用
收藏
页码:938 / 944
页数:7
相关论文
共 41 条
[1]   Level II lymph nodes and radiation-induced xerostomia [J].
Astreinidou, E ;
Dehnad, H ;
Terhaard, CHJ ;
Raaijmakers, CPJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (01) :124-131
[2]   A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error [J].
Beckham, WA ;
Keall, PJ ;
Siebers, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19) :3465-3473
[3]  
Bel A, 2003, RADIOTHER ONCOL, V68, pS18
[4]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[5]   A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility [J].
Bel, A ;
Petrascu, O ;
Van de Vondel, I ;
Coppens, L ;
Linthout, N ;
Verellen, D ;
Storme, G .
MEDICAL PHYSICS, 2000, 27 (02) :354-358
[6]  
Bortfeld T, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P1
[7]   When should systematic patient positioning errors in radiotherapy be corrected? [J].
Bortfeld, T ;
van Herk, M ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (23) :N297-N302
[8]   DECOMPOSITION OF PENCIL BEAM KERNELS FOR FAST DOSE CALCULATIONS IN 3-DIMENSIONAL TREATMENT PLANNING [J].
BORTFELD, T ;
SCHLEGEL, W ;
RHEIN, B .
MEDICAL PHYSICS, 1993, 20 (02) :311-318
[9]   The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms [J].
Cho, BCJ ;
van Herk, M ;
Mijnheer, BJ ;
Bartelink, H .
MEDICAL PHYSICS, 2002, 29 (10) :2305-2318
[10]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invariance [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2001-2011