Automated liquid chromatography-tandem mass spectrometry method for the analysis of firocoxib in urine and plasma from horse and dog

被引:15
作者
Letendre, Laura
Kvaternick, Valerie
Tecle, Berhane
Fischer, James
机构
[1] Merial Limited, Pharmacokinetics and Drug Metabolism, NJ
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 853卷 / 1-2期
关键词
LC-MS/MS; NSAID; urine; plasma; automation; firocoxib; horse; dog;
D O I
10.1016/j.jchromb.2007.03.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rugged, sensitive and efficient liquid chromatography-tandem mass spectrometry method was developed and validated for the quantitative analysis of firocoxib in urine from 5 to 3000 ng/mL and in plasma from I to 3000 ng/mL. The method requires 200 mu L of either plasma or urine and includes sample preparation in 96-well solid phase extraction (SPE) plates using a BIOMEK (R) 2000 Laboratory Automated Workstation. Chromatographic separation of firocoxib from matrix interferences was achieved using isocratic reversed phase chromatography on a PHENOMENEX LUNA (R) Phenyl-Hexyl column. The mobile phase was 45% acetonitrile and 55% of a 2 mM ammonium formate buffer. The method was accurate (88-107%) and precise (CV < 12.2%) within and between sets. Extraction efficiencies (recovery) > 93% were achieved and ionization efficiencies (due to matrix effects) were > 72%. Extensive stability and ruggedness testing was also performed; therefore, the method can be used for pharmacokinetic studies as well as drug monitoring and screening. The data presented here is the first LC-MS/MS method for the quantitation of firocoxib in plasma (LLOQ of 1 ng/mL), a 25-fold improvement in sensitivity over the HPLC-UV method and the first quantitative method for firocoxib in urine (LLOQ of 5 ng/mL). Additionally the sample preparation process has been automated to improve efficiency. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 345
页数:13
相关论文
共 23 条
[11]   Role of cyclooxygenase-2 in gastric mucosal defense [J].
Peskar, BM ;
Maricic, N ;
Gretzer, B ;
Schuligoi, R ;
Schmassmann, A .
LIFE SCIENCES, 2001, 69 (25-26) :2993-3003
[12]   An overview of the recent developments in analytical methodologies for determination of COX-2 inhibitors in bulk drugs, pharmaceuticals and biological matrices [J].
Rao, RN ;
Meena, S ;
Rao, AR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :349-363
[13]   HPLC determination and pharmacokinetic study of valdecoxib in human plasma [J].
Sane, RT ;
Menon, S ;
Deshpande, AY ;
Jain, A .
CHROMATOGRAPHIA, 2005, 61 (3-4) :137-141
[14]  
Short CR, 1998, J VET PHARMACOL THER, V21, P145, DOI 10.1046/j.1365-2885.1998.00115.x
[15]   Simultaneous determination of celecoxib, hydroxycelecoxib, and carboxycelecoxib in human plasma using gradient reversed-phase liquid chromatography with ultraviolet absorbance detection [J].
Störmer, E ;
Bauer, S ;
Kirchheiner, J ;
Brockmöller, J ;
Roots, I .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01) :207-212
[16]   Pharmacokinetics of meloxicam in plasma and urine of horses [J].
Toutain, PL ;
Reymond, N ;
Laroute, V ;
Garcia, P ;
Popot, MA ;
Bonnaire, Y ;
Hirsch, A ;
Narbe, R .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2004, 65 (11) :1542-1547
[17]   Monolithic silica liquid chromatography columns for the determination of cyclooxygenase II inhibitors in human plasma [J].
Vallano, PT ;
Mazenko, RS ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 779 (02) :249-257
[18]   Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples [J].
Vintiloiu, A ;
Mullett, WM ;
Papp, R ;
Lubda, D ;
Kwong, E .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) :150-157
[19]   Investigation of the pharmacokinetics of celecoxib by liquid chromatography-mass spectrometry [J].
Werner, U ;
Werner, D ;
Pahl, A ;
Mundkowski, R ;
Gillich, M ;
Brune, K .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (01) :56-60
[20]   Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma [J].
Wiesner, JL ;
de Jager, AD ;
Sutherland, FCW ;
Hundt, HKL ;
Swart, KJ ;
Hundt, AF ;
Els, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01) :115-121