Digital breast tomosynthesis versus digital mammography: a clinical performance study

被引:205
作者
Gennaro, Gisella [1 ]
Toledano, Alicia [2 ]
di Maggio, Cosimo [3 ]
Baldan, Enrica [1 ]
Bezzon, Elisabetta [1 ]
La Grassa, Manuela [4 ]
Pescarini, Luigi [1 ,3 ]
Polico, Ilaria [1 ]
Proietti, Alessandro [1 ]
Toffoli, Aida [1 ]
Muzzio, Pier Carlo [1 ,5 ]
机构
[1] IRCCS, Venetian Oncol Inst IOV, Dept Radiol, I-35128 Padua, Italy
[2] Stat Collaborat Inc, Washington, DC USA
[3] Univ Padua, Dept Oncol & Surg Sci, Padua, Italy
[4] IRCCS, Aviano Oncol Reference Ctr CRO, Dept Radiol, Aviano, Pordenone, Italy
[5] Univ Padua, Dept Med Diagnost Sci, Padua, Italy
关键词
Digital breast tomosynthesis; Digital mammography; ROC analysis; Clinical performance; Non-inferiority; COMPUTER-AIDED DETECTION; RADIATION; SYSTEM; EXPERIENCE; SIMULATION; ACCURACY; PLATFORM; MASSES;
D O I
10.1007/s00330-009-1699-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views.
引用
收藏
页码:1545 / 1553
页数:9
相关论文
共 33 条
[1]   Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings [J].
Andersson, Ingvar ;
Ikeda, Debra M. ;
Zackrisson, Sophia ;
Ruschin, Mark ;
Svahn, Tony ;
Timberg, Pontus ;
Tingberg, Anders .
EUROPEAN RADIOLOGY, 2008, 18 (12) :2817-2825
[2]   Computer-aided detection of masses in digital tomosynthesis mammography: Comparison of three approaches [J].
Chan, Heang-Ping ;
Wei, Jun ;
Zhang, Yiheng ;
Helvie, Mark A. ;
Moore, Richard H. ;
Sahiner, Berkman ;
Hadjiiski, Lubomir ;
Kopans, Daniel B. .
MEDICAL PHYSICS, 2008, 35 (09) :4087-4095
[3]   Computer-aided detection system for breast masses on digital tomosynthesis mammograms: Preliminary experience [J].
Chan, HP ;
Wei, J ;
Sahiner, B ;
Rafferty, EA ;
Wu, T ;
Roubidoux, MA ;
Moore, RH ;
Kopans, DB ;
Hadjiiski, LM ;
Helvie, MA .
RADIOLOGY, 2005, 237 (03) :1075-1080
[4]   A mathematical model platform for optimizing a multiprojection breast imaging system [J].
Chawla, Amarpreet S. ;
Samei, Ehsan ;
Saunders, Robert S. ;
Lo, Joseph Y. ;
Baker, Jay A. .
MEDICAL PHYSICS, 2008, 35 (04) :1337-1345
[5]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[6]   Dose comparison between screen/film and full-field digital mammography [J].
Gennaro, Gisella ;
di Maggio, Cosimo .
EUROPEAN RADIOLOGY, 2006, 16 (11) :2559-2566
[7]   A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging [J].
Gong, X ;
Glick, SJ ;
Liu, B ;
Vedula, AA ;
Thacker, S .
MEDICAL PHYSICS, 2006, 33 (04) :1041-1052
[8]   Digital breast tomosynthesis: A pilot observer study [J].
Good, Walter F. ;
Abrams, Gordon S. ;
Catullo, Victor J. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :865-869
[9]   A comparison of denominator degrees of freedom methods for multiple observer ROC analysis [J].
Hillis, Stephen L. .
STATISTICS IN MEDICINE, 2007, 26 (03) :596-619
[10]   Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum plus silver x-ray anode-filter combinations [J].
Ma, Andy K. W. ;
Darambara, Dimitra G. ;
Stewart, Alexander ;
Gunn, Spencer ;
Bullard, Edward .
MEDICAL PHYSICS, 2008, 35 (12) :5278-5289