Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: Feasibility study in rabbits

被引:47
作者
Yang, XM [1 ]
Atalar, E [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Outpatient Ctr, Baltimore, MD 21287 USA
关键词
animals; interventional procedures; experimental studies; magnetic resonance (MR); contrast enhancement; guidance; vascular studies;
D O I
10.1148/radiology.217.2.r00oc17501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To develop a technique for intravascular magnetic resonance (MR)guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS: An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use with interventional devices. Laparotomy was performed in eight rabbits, and a dilatable stenosis was created at the upper abdominal aorta. Balloon angioplasty, Validated at pre- and postoperative MR aortography with renal contrast enhancement was performed by using a 1.5-T MR unit with a fast spoiled gradient-echo pulse sequence, short repetition and echo times, and a rate of three frames per second. RESULTS: During MR tracking, the entire length of the MR imaging guide wire was always visible as a band of high signal intensity. In all cases, the MR imaging guide wires were passed through the aortic stenoses dilated by means of balloon inflation. Before balloon angioplasty, flow in the aorta distal to the stenosis was decreased, which caused mild contrast enhancement in each kidney. After balloon angioplasty, distal flow was restored, resulting in substantial renal enhancement. CONCLUSION: The MR imaging guide wire is a potential tool for use in endovascular interventional MR imaging.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 18 条
[1]   Visualization of MR-compatible catheters by electrically induced local field inhomogeneities:: Evaluation in vivo [J].
Adam, G ;
Glowinski, A ;
Neuerburg, J ;
Bücker, A ;
van Vaals, JJ ;
Günther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :209-213
[2]   Catheter-tracking FOV MR fluoroscopy [J].
Atalar, E ;
Kraitchman, DL ;
Carkhuff, B ;
Lesho, J ;
Ocali, O ;
Solaiyappan, M ;
Guttman, MA ;
Charles, HK .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :865-872
[3]   MR-guided endovascular interventions: Susceptibility-based catheter and near-real-time imaging technique [J].
Bakker, CJ ;
Hoogeveen, RM ;
Hurtak, WF ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WPTM .
RADIOLOGY, 1997, 202 (01) :273-276
[4]   MR-guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions [J].
Bakker, CJ ;
Smits, HF ;
Bos, C ;
van der Weide, R ;
Zuiderveld, KJ ;
van Vaals, JJ ;
Hurtak, WF ;
Viergever, MA ;
Mall, WP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :245-250
[5]   Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition [J].
Correia, LCL ;
Atalar, E ;
Kelemen, MD ;
Ocali, O ;
Hutchins, GM ;
Fleg, JL ;
Gerstenblith, G ;
Zerhouni, EA ;
Lima, JAC .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 1997, 17 (12) :3626-3632
[6]   Catheter visualization using locally induced, actively controlled field inhomogeneities [J].
Glowinski, A ;
Adam, G ;
Bucker, A ;
Neuerburg, J ;
vanVaals, JJ ;
Gunther, RW .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) :253-258
[7]  
Guide for the Care and Use of Laboratory Animals, GUID CAR US LAB AN
[8]   VASCULAR INTERVENTIONS GUIDED BY ULTRAFAST MR-IMAGING - EVALUATION OF DIFFERENT MATERIALS [J].
KOCHLI, VD ;
MCKINNON, GC ;
HOFMANN, E ;
VONSCHULTHESS, GK .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :309-314
[9]   Active MR visualization of a vascular guidewire in vivo [J].
Ladd, ME ;
Zimmermann, GG ;
Quick, HH ;
Debatin, JF ;
Boesiger, P ;
von Schulthess, GK ;
McKinnon, GC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :220-225
[10]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270