Amperometric hydrogen peroxide biosensor with sol-gel/chitosan network-like film as immobilization matrix

被引:201
作者
Wang, G
Xu, JJ
Chen, HY
Lu, ZH
机构
[1] Nanjing Univ, Inst Analyt Sci, Dept Chem, Lab Mesoscop Mat Sci, Nanjing 210093, Peoples R China
[2] SE Univ, Natl Lab Mol & Biomol Elect, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
sol-gel/chitosan composite film; horseradish peroxidase; biosensor; hydrogen peroxide; HORSERADISH-PEROXIDASE; ENZYME SENSOR; GEL; CHITOSAN; MEMBRANE; COIMMOBILIZATION; CONSTRUCTION; ELECTRODES; OXIDASE;
D O I
10.1016/S0956-5663(02)00152-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new type of sol-gel/organic hybrid composite material based on the cross-linking of natural polymer chitosan with (3-aoryloxypropyl) dimethoxymethylsilane was developed for the fabrication of an amperometric H2O2 biosensor. The composite film was used to immobilize horseradish peroxidase (HRP) on a gold disk electrode. The properties of sol-gel/chitosan and sol-gel/chitosan-HRP films have been carefully characterized by atomic force microscopy and Fourier transform infrared. By using fluorescent label, a protein density on sol-gel/chitosan has been calculated to be 3.14 x 10(12) molecules cm(-2). With the aid of catechol mediator, the biosensor had a fast response of less than 2 s with linear range of 5.0 x 10(-9)-1.0 X 10(-7) mol l(-1) and a detection limit of 2 x 10(-9) mol l(-1). Its current response shows a typical Michaelis-Menten mechanism. The apparent Michaelis-Menten constant K-M(app) is found to be 1.30 mumol l(-1). The activation energy for enzymatic reaction is calculated to be 8.22 kJ mol(-1). The biosensor retained approximately 75% of its original activity after about 60 days of storage in a phosphate buffer at 4 degreesC. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 40 条
[11]  
2-M
[12]   ENZYME SENSOR FOR L-LACTATE WITH A CHITOSAN-MERCURY FILM ELECTRODE [J].
HIKIMA, S ;
KAKIZAKI, T ;
TAGA, M ;
HASEBE, K .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (8-9) :607-609
[13]   NETWORK, STRUCTURE OF INORGANIC-ORGANIC HYBRID GELS [J].
KAJIWARA, K ;
KRAKOVSKY, I ;
URAKAWA, H ;
KOHJIYA, S .
MACROMOLECULAR SYMPOSIA, 1995, 93 :11-16
[14]   FOURIER SELF-DECONVOLUTION - A METHOD FOR RESOLVING INTRINSICALLY OVERLAPPED BANDS [J].
KAUPPINEN, JK ;
MOFFATT, DJ ;
MANTSCH, HH ;
CAMERON, DG .
APPLIED SPECTROSCOPY, 1981, 35 (03) :271-276
[15]   Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film [J].
Kumar, A ;
Malhotra, R ;
Malhotra, BD ;
Grover, SK .
ANALYTICA CHIMICA ACTA, 2000, 414 (1-2) :43-50
[16]  
LEV O, 1992, ANALUSIS, V20, P543
[17]   Applications of amperometric silica sol-gel modified enzyme biosensors [J].
Li, J ;
Tan, SN .
ANALYTICAL LETTERS, 2000, 33 (08) :1467-1477
[18]   Mediated amperometric glucose sensor modified by the sol-gel method [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN ;
Ge, H .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) :135-141
[19]   A reagentless amperometric biosensor based on the coimmobilization of horseradish peroxidase and methylene green in a modified zeolite matrix [J].
Liu, BH ;
Yan, F ;
Kong, JL ;
Deng, JQ .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :31-39
[20]   Amperometric hydrogen peroxide biosensor based on immobilization of peroxidase in chitosan matrix crosslinked with glutaraldehyde [J].
Miao, YQ ;
Tan, SN .
ANALYST, 2000, 125 (09) :1591-1594