Behaviourally induced changes in extracellular levels of brain glutamate monitored at 1 s resolution with an implanted biosensor

被引:38
作者
Lowry, JP [1 ]
Ryan, MR [1 ]
O'Neill, RD [1 ]
机构
[1] Univ Coll Dublin, Dept Chem, Dublin 4, Ireland
来源
ANALYTICAL COMMUNICATIONS | 1998年 / 35卷 / 03期
关键词
D O I
10.1039/a708747k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor for L-glutamic acid (Glu), constructed by immobilisation of L-glutamate oxidase onto lipid-coated 60 mu m radius Pt wire with poly(o-phenylenediamine), nas used amperometrically in attempts to detect glutamate in brain extracellular fluid (ECF) in the awake, freely moving rat at 1 s intervals, An implanted carbon paste electrode served to monitor simultaneous changes in brain ascorbate (AA), There were spontaneous, parallel changes in both signals, depending on the behavioural state of the animal, giving rise to a significant positive correlation coefficient between the two variables. The application of a mild stressor (10 s tail pinch) caused an immediate increase in both signals, The effects of inhibiting energy metabolism, together with an existing hypothesis linking Glu and AA in the ECF, were used to conclude that AA does not interfere electrochemically with the biosensor in vivo, that there are parallel changes in extracellular Glu and AA concentrations under normal physiological conditions, and that sub-micromolar physiologically related changes in brain Glu could be detected in the ECF several days after implantation of the electrodes.
引用
收藏
页码:87 / 89
页数:3
相关论文
共 25 条
[1]   THE DIALYSIS ELECTRODE - A NEW METHOD FOR INVIVO MONITORING [J].
ALBERY, WJ ;
BOUTELLE, MG ;
GALLEY, PT .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (12) :900-901
[2]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021
[3]   CELLULAR-ORIGINS OF ENDOGENOUS AMINO-ACIDS RELEASED INTO THE EXTRACELLULAR FLUID OF THE RAT STRIATUM DURING SEVERE INSULIN-INDUCED HYPOGLYCEMIA [J].
BUTCHER, SP ;
SANDBERG, M ;
HAGBERG, H ;
HAMBERGER, A .
JOURNAL OF NEUROCHEMISTRY, 1987, 48 (03) :722-728
[4]   EFFECTS OF APOMORPHINE AND L-METHIONINE SULFOXIMINE ON THE RELEASE OF EXCITATORY AMINO-ACID NEUROTRANSMITTERS AND GLUTAMINE IN THE STRIATUM OF THE CONSCIOUS RAT [J].
EXPOSITO, I ;
SANZ, B ;
PORRAS, A ;
MORA, F .
EUROPEAN JOURNAL OF NEUROSCIENCE, 1994, 6 (02) :287-291
[5]   Lactate and excitatory amino acids measured by microdialysis are decreased by pentobarbital coma in head-injured patients [J].
Goodman, JC ;
Valadka, AB ;
Gopinath, SP ;
Cormio, M ;
Robertson, CS .
JOURNAL OF NEUROTRAUMA, 1996, 13 (10) :549-556
[6]   On the release of glutamate and aspartate in the basal ganglia of the rat: Interactions with monoamines and neuropeptides [J].
HerreraMarschitz, M ;
Goiny, M ;
You, ZB ;
Meana, JJ ;
Pettersson, E ;
RodriguezPuertas, R ;
Xu, ZQ ;
Terenius, L ;
Hokfelt, T ;
Ungerstedt, U .
NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 1997, 21 (04) :489-495
[7]   DIRECT MEASUREMENT OF GLUTAMATE RELEASE IN THE BRAIN USING A DUAL ENZYME-BASED ELECTROCHEMICAL SENSOR [J].
HU, YB ;
MITCHELL, KM ;
ALBAHADILY, FN ;
MICHAELIS, EK ;
WILSON, GS .
BRAIN RESEARCH, 1994, 659 (1-2) :117-125
[8]   Evidence for uncoupling of oxygen and glucose utilization during neuronal activation in rat striatum [J].
Lowry, JP ;
Fillenz, M .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 498 (02) :497-501
[9]   CHARACTERIZATION OF GLUCOSE OXIDASE-MODIFIED POLY(PHENYLENEDIAMINE)-COATED ELECTRODES IN-VITRO AND IN-VIVO - HOMOGENEOUS INTERFERENCE BY ASCORBIC-ACID IN HYDROGEN-PEROXIDE DETECTION [J].
LOWRY, JP ;
MCATEER, K ;
ELATRASH, SS ;
DUFF, A ;
ONEILL, RD .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1754-1761
[10]   EFFICIENT GLUCOSE DETECTION IN ANAEROBIC SOLUTIONS USING AN ENZYME-MODIFIED ELECTRODE DESIGNED TO DETECT H2O2 - IMPLICATIONS FOR BIOMEDICAL APPLICATIONS [J].
LOWRY, JP ;
MCATEER, K ;
ELATRASH, SS ;
ONEILL, RD .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (21) :2483-2484