Non-contact photothermal control of enzyme reactions on a microchip by using a compact diode laser

被引:76
作者
Tanaka, Y
Slyadnev, MN
Hibara, A
Tokeshi, M
Kitamori, T
机构
[1] Univ Tokyo, Dept Appl Chem, Sch Engn, Bunkyo Ku, Tokyo 1138656, Japan
[2] Kanagawa Acad Sci & Technol, Integrated Chem Project, Kawasaki, Kanagawa 2130012, Japan
关键词
microchips; microchannels; thermal lens detection; instrumentation; diaminobenzidine tetrahydrochloride; peroxidase; enzymes; hydrogen peroxide;
D O I
10.1016/S0021-9673(00)00593-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Photothermal temperature control of an enzyme-catalyzed reaction in a microchip using a diode laser was demonstrated. A laser beam with energy of 10 mW was used to irradiate an absorbing target placed on top of the microchip cover plate. Theoretical calculations have shown that temperature in the microchannel can be locally increased by 5-7 degrees C during short time intervals, due to heat released by the target. The rate of the enzyme reaction, which was initially inhibited due to cooling of the chip to low temperature, was increased when the target was irradiated. The products were detected by a thermal lens microscope. The product concentration was shown to depend on irradiation time, laser intensity and substrate concentration. Reaction characteristics (rate constant of the reaction) were then derived from these dependencies. The reaction volume and absolute quantity of the reaction product were estimated as 10 nl and 100 fmol, respectively. It was also demonstrated that a direct solvent heating method using infrared radiation could control the reaction in the microchannel. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 18 条
[11]   Molecular transport between two phases in a microchannel [J].
Sato, K ;
Tokeshi, M ;
Sawada, T ;
Kitamori, T .
ANALYTICAL SCIENCES, 2000, 16 (05) :455-456
[12]   Sub-zeptomole detection in a microfabricated glass channel by thermal-lens microscopy [J].
Sato, K ;
Kawanishi, H ;
Tokeshi, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1999, 15 (06) :525-529
[13]   Integration of flow injection analysis and zeptomole-level detection of the Fe(II)-o-phenanthroline complex [J].
Sato, K ;
Tokeshi, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1999, 15 (07) :641-645
[14]   Integration of an immunosorbent assay system: Analysis of secretory human immunoglobulin A on polystyrene beads in a microchip [J].
Sato, K ;
Tokeshi, M ;
Odake, T ;
Kimura, H ;
Ooi, T ;
Nakao, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1144-1147
[15]   Fully automated DNA reaction and analysis in a fluidic capillary instrument [J].
Swerdlow, H ;
Jones, BJ ;
Wittwer, CT .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :848-855
[16]   Integration of a microextraction system on a glass chip:: Ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride [J].
Tokeshi, M ;
Minagawa, T ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1711-1714
[17]   Multiple sample PCR amplification and electrophoretic analysis on a microchip [J].
Waters, LC ;
Jacobson, SC ;
Kroutchinina, N ;
Khandurina, J ;
Foote, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5172-5176
[18]   Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device [J].
Woolley, AT ;
Hadley, D ;
Landre, P ;
deMello, AJ ;
Mathies, RA ;
Northrup, MA .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4081-4086