High frequency nonlinear B-scan imaging of microbubble contrast agents

被引:118
作者
Goertz, DE
Cherin, E
Needles, A
Karshafian, R
Brown, AS
Burns, PN
Foster, FS
机构
[1] Univ Toronto, Mouse Imaging Ctr, Toronto, ON, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
D O I
10.1109/TUFFC.2005.1397351
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
It previously was shown that it is possible to produce nonlinear scattering from microbubble contrast agents using transmit frequencies in the 14-32 MHz range, suggesting the possibility of performing high-frequency, nonlinear microbubble imaging. In this study, we describe the development of nonlinear microbubble B-scan imaging instrumentation capable of operating at transmit center frequencies between 10 and 50 MHz. The system underwent validation experiments using transmit frequencies of 20 and 30 MHz. Agent characterization experiments demonstrate the presence of nonlinear scattering for the conditions used in this study. Using wall-less vessel phantoms, nonlinear B-scan imaging is performed using energy in one of the subharmonic, ultraharmonic, and second harmonic frequency regions for transmit frequencies of 20 and 30 MHz. Both subharmonic and ultraharmonic imaging modes achieved suppression of tissue signals to below the noise floor while achieving contrast to noise ratios of up to 26 and 17 dB, respectively. The performance of second harmonic imaging was compromised by nonlinear propagation and offered no significant contrast improvement over fundamental mode imaging. In vivo experiments using the subharmonic of a 20 MHz transmit pulse show the successful detection of microvessels Is in the rabbit ear and in the mouse heart. The results of this study demonstrate the feasibility of nonlinear microbubble imaging at high frequencies.
引用
收藏
页码:65 / 79
页数:15
相关论文
共 62 条
[11]   A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Starkoski, BG ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :997-1015
[12]  
CHRISTOPHER DA, 1998, THESIS U TORONTO ONT
[13]   A THEORETICAL-STUDY OF CAVITATION GENERATED BY AN EXTRACORPOREAL SHOCK-WAVE LITHOTRIPTER [J].
CHURCH, CC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 86 (01) :215-227
[14]   Detection procedures of ultrasound contrast agents [J].
de Jong, N ;
Frinking, PJA ;
Bouakaz, A ;
Ten Cate, FJ .
ULTRASONICS, 2000, 38 (1-8) :87-92
[15]   ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS [J].
DEJONG, N ;
HOFF, L ;
SKOTLAND, T ;
BOM, N .
ULTRASONICS, 1992, 30 (02) :95-103
[16]   HIGHER HARMONICS OF VIBRATING GAS-FILLED MICROSPHERES .2. MEASUREMENTS [J].
DEJONG, N ;
CORNET, R ;
LANCEE, CT .
ULTRASONICS, 1994, 32 (06) :455-459
[17]   In vivo targeting of acoustically reflective liposomes for intravascular and transvascular ultrasonic enhancement [J].
Demos, SM ;
Alkan-Onyuksel, H ;
Kane, BJ ;
Ramani, K ;
Nagaraj, A ;
Greene, R ;
Klegerman, M ;
McPherson, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (03) :867-875
[18]   A review of physical phenomena associated with ultrasonic contrast agents and illustrative clinical applications [J].
Deng, CX ;
Lizzi, FL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03) :277-286
[19]   Imaging and spectrum analysis of contrast agents in the in vivo rabbit eye using very-high-frequency ultrasound [J].
Deng, CX ;
Lizzi, FL ;
Silverman, RH ;
Ursea, R ;
Coleman, DJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :383-394
[20]   NUMERICAL-STUDIES OF THE SPECTRUM OF LOW-INTENSITY ULTRASOUND SCATTERED BY BUBBLES [J].
EATOCK, BC ;
NISHI, RY ;
JOHNSTON, GW .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1985, 77 (05) :1692-1701