Single Arc Volumetric Modulated Arc Therapy of head and neck cancer

被引:216
作者
Bertelsen, Anders [1 ,2 ]
Hansen, Christian R. [2 ]
Johansen, Jorgen [3 ]
Brink, Carsten [1 ,2 ]
机构
[1] Univ So Denmark, Inst Clin Res, Odense, Denmark
[2] Odense Univ Hosp, Lab Radiat Phys, DK-5000 Odense, Denmark
[3] Odense Univ Hosp, Dept Oncol, DK-5000 Odense, Denmark
关键词
Volumetric Modulated Arc Therapy; VMAT; SmartArc; Head and neck; Step-and-shoot intensity modulated radiotherapy; IMAGE-GUIDANCE; IMRT; RADIOTHERAPY; DAHANCA; CARCINOMA; DELIVERY; RAPIDARC;
D O I
10.1016/j.radonc.2010.01.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Background: The quality of Volumetric Modulated Arc Therapy (VMAT) plans is highly dependent on the performance of the optimization algorithm used. Recently new algorithms have become available which are capable of generating VMAT plans for Elekta accelerators. The VMAT algorithm in Pinnacle(3)(R) is named SmartArc and its capability to generate treatment plans for head and neck cancer was tested. Methods: Twenty-five patients with oropharyngeal or hypopharyngeal carcinoma, previously treated with IMRT by means of Pinnacle(3)(R) and Elekta accelerators, were replanned with single arc VMAT. The VMAT planning objectives were to achieve clinical target coverage and sparing of the organs at risk (OAR). Comparison with the original clinically used IMRT was made by evaluating (1) dose-volume histograms (DVHs) for PTVs, (2) DVHs for OARs, (3) delivery time and monitor units (MU), and (4) treatment accuracy. Results: Equivalent or superior target coverage and sparing of OARs were achieved with VMAT compared to IMRT. Volumes in the healthy tissues receiving between 17.3 Gy and 49.4 Gy were significantly reduced and the conformity (CI95%) of the elective PTV was improved from 1.7 with IMRT to 1.6 with VMAT. Compared to step-and-shoot IMRT, VMAT reduced the number of MUs by 8.5% to 460 +/- 63 MUs per fraction, and delivered on an Elekta Synergy accelerator, the treatment time was on average reduced by 35% to 241 +/- 16 s. In Delta(4)(R) measurements of the VMAT treatments, 99.6 +/- 0.5% of the detector points passed a 3 mm and 3% gamma criterion, identical to the results of IMRT. Conclusions: The target coverages obtained in the IMRT and VMAT plans were found to be very similar. SmartArc generated single arc VMAT plans with equivalent or better target coverage and sparing of OARs compared to IMRT, while both delivery time and MUs were decreased. Very good dose accuracy results were obtained delivering the plans on an Elekta accelerator. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 95 (2010) 142-148
引用
收藏
页码:142 / 148
页数:7
相关论文
共 24 条
[1]
Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study [J].
Bedford, James L. ;
Hansen, Vibeke Nordmark ;
Mcnair, Helen A. ;
Aitken, Alexandra H. ;
Brock, Juliet E. C. ;
Warrington, Alan P. ;
Brada, Michael .
ACTA ONCOLOGICA, 2008, 47 (07) :1438-1443
[2]
Evaluation of the Delta4 phantom for IMRT and VMAT verification [J].
Bedford, James L. ;
Lee, Young K. ;
Wai, Philip ;
South, Christopher P. ;
Warrington, Alan P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :N167-N176
[3]
COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) [J].
Bedford, James L. ;
Warrington, Alan P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :537-545
[4]
Development and evaluation of an efficient approach to volumetric arc therapy planning [J].
Bzdusek, Karl ;
Friberger, Henrik ;
Eriksson, Kjell ;
Hardemark, Bjorn ;
Robinson, David ;
Kaus, Michael .
MEDICAL PHYSICS, 2009, 36 (06) :2328-2339
[5]
Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT [J].
Clivio, Alessandro ;
Fogliata, Antonella ;
Franzetti-Pellanda, Alessandra ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Wyttenbach, Rolf ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) :118-124
[6]
A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191
[7]
DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY [J].
Den, Robert B. ;
Doemer, Anthony ;
Kubicek, Greg ;
Bednarz, Greg ;
Galvin, James M. ;
Keane, William M. ;
Xiao, Ying ;
Machtay, Mitchell .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05) :1353-1359
[8]
Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115
[9]
Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniques [J].
Fogliata, Antonella ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) :254-262
[10]
CT-based delineation of lymph node levels and related CTVs in the node-negative neck:: DAHANCA, EORTC, GORTEC, NCIC, RTOG consensus guidelines [J].
Grégoire, V ;
Levendag, P ;
Ang, KK ;
Bernier, J ;
Braaksma, M ;
Budach, V ;
Chao, C ;
Coche, E ;
Cooper, JS ;
Cosnard, G ;
Eisbruch, A ;
El-Sayed, S ;
Emami, B ;
Grau, C ;
Hamoir, M ;
Lee, N ;
Maingon, P ;
Muller, K ;
Reychler, H .
RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) :227-236