Current calibration, treatment, and treatment planning techniques among institutions participating in the Children's Oncology Group

被引:16
作者
Urie, M
FitzGerald, TJ
Followill, D
Laurie, F
Marcus, R
Michalski, J
机构
[1] Qual Assurance Review Ctr, Providence, RI 02908 USA
[2] Univ Massachusetts, Sch Med, Worcester, MA USA
[3] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[4] Emory Univ, Sch Med, Atlanta, GA USA
[5] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 01期
关键词
D O I
10.1016/S0360-3016(02)03827-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report current technology implementation, radiation therapy physics and treatment planning practices, and results of treatment planning exercises among 261 institutions belonging to the Children's Oncology Group (COG). Methods and Materials: The Radiation Therapy Committee of the newly formed COG mandated that each institution demonstrate basic physics and treatment planning abilities by satisfactorily completing a questionnaire and four treatment planning exercises designed by the Quality Assurance Review Center. The planning cases are (1) a maxillary sinus target volume (for two-dimensional planning), (2) a Hodgkin's disease mantle field (for irregular-field and off-axis dose calculations), (3) a central axis blocked case, and (4) a craniospinal irradiation case. The questionnaire and treatment plans were submitted (as of 1/30/02) by 243 institutions and completed satisfactorily by 233. Data from this questionnaire and analyses of the treatment plans with monitor unit calculations are presented. Results: Of the 243 clinics responding, 54% use multileaf collimators routinely, 94% use asymmetric jaws routinely, and 13% use dynamic wedges. Nearly all institutions calibrate their linear accelerators following American Association of Physicists in Medicine protocols, currently 16% with TG-51 and 81% with TG-21 protocol. Treatment planning systems are relied on very heavily for all calculations, including monitor units. Techniques and results of each of the treatment planning exercises are presented. Conclusions: Together, these data provide a unique compilation of current (2001) radiation therapy practices in institutions treating pediatric patients. Overall, the COG facilities have the equipment and the personnel to perform high-quality radiation therapy. With ongoing quality assurance review, radiation therapy compliance with COG protocols should be high. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:245 / 260
页数:16
相关论文
共 21 条
[11]   Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom [J].
Kron, T ;
Hamilton, C ;
Roff, M ;
Denham, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (02) :566-579
[12]   A glance on quality assurance in EORTC study 22922 evaluating techniques for internal mammary and medial supraclavicular lymph node chain irradiation in breast cancer [J].
Lievens, Y ;
Poortmans, P ;
Van den Bogaert, W .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) :257-265
[13]   The potential impact of treatment variations on the results of radiotherapy of the internal mammary lymph node chain: A quality-assurance report on the dummy run of EORTC phase III randomized trial 22922/10925 in stage I-III breast cancer [J].
Poortmans, PMP ;
Venselaar, JLM ;
Struikmans, H ;
Hurkmans, CW ;
Davis, JB ;
Huyskens, D ;
van Tienhoven, G ;
Vlaun, V ;
Lagendijk, JJW ;
Mijnheer, BJ ;
De Winter, KA ;
Van der Hulst, MH ;
Van den Bogaert, WFC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05) :1399-1408
[14]  
Purdy JA, 1998, STRAHLENTHER ONKOL, V174, P2
[15]  
*RAD THER COMM, 1994, MED PHYS, P581
[16]  
SCHULZ J, 1983, MED PHYS, V10, P741
[17]  
SEBAGMONTEFIORE DJ, 1992, INT J RADIAT ONCOL, V2, P144
[18]  
STAAR S, 2001, INT J RAD ONCOL B S1, V51, P125
[19]   Quality assurance of the EORTC radiotherapy trial 22931 for head and neck carcinomas: the dummy run [J].
Valley, JF ;
Bernier, J ;
Tercier, PA ;
Fogliata-Cozzi, A ;
Rosset, A ;
Garavaglia, G ;
Mirimanoff, RO .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (01) :37-44
[20]   The START Trial - measurements in semi-anatomical breast and chest wall phantoms [J].
Venables, K ;
Winfield, E ;
Deighton, A ;
Aird, E ;
Hoskin, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1937-1948