A PC-AT based program for conversion of magnetic resonance imaging (MRI) scans into coordinate input for finite element mesh generation is presented. The program is written in Borland C + +3.1 and is compatible with every general-use personal computer, permitting the use of MS-DOS3.0 or higher with a Microsoft mouse. The program is menu driven and does not demand specialised knowledge from the user. The system and memory requirements are minimal -640 kB RAM - and it runs as a stand-alone program. A second program allows the construction of a three-dimensional representation of the limb sub-structure and generation of the FE mesh from the converted cross-sectional scans. The capabilities of the program are demonstrated using cross-sectional scans of the upper arm; the fat, muscle and bone contours were obtained to a very high level of precision (0.4,nm). (C) 1997 IPEM Published by Elsevier Science Ltd.
引用
收藏
页码:681 / 689
页数:9
相关论文
共 16 条
[11]
SilverThorn MB, 1996, J REHABIL RES DEV, V33, P227
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
ZHANG, M
LORD, M
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
LORD, M
TURNERSMITH, AR
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
TURNERSMITH, AR
ROBERTS, VC
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
ZHANG, M
LORD, M
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
LORD, M
TURNERSMITH, AR
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill
TURNERSMITH, AR
ROBERTS, VC
论文数: 0引用数: 0
h-index: 0
机构:Centre of Rehabilitation Engineering, Department of Medical Engineering and Physics, King's College School of Medicine and Dentistry, London, SE5 9RS, Denmark Hill