Subfemtomole MS and MS/MS peptide sequence analysis using nano-HPLC micro-ESI Fourier transform ion cyclotron resonance mass spectrometry

被引:281
作者
Martin, SE [1 ]
Shabanowitz, J [1 ]
Hunt, DF [1 ]
Marto, JA [1 ]
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22904 USA
关键词
D O I
10.1021/ac000497v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Subfemtomole peptide sequence analysis has been achieved using microcapillary HPLC columns, with integrated nanoelectrospray emitters, coupled directly to a Fourier transform ion cyclotron resonance mass spectrometer. Accurate mass (+/-0.010 Da) peptide maps are generated from a standard six-protein digest mixture, whose principle components span a concentration dynamic range of 1000:1. Iterative searches against similar to 189 000 entries in the OWL database readily identify each protein, with high sequence coverage (20-60%), from as little as 10 amol loaded on-column. In addition, a simple variable-flow HPLC apparatus provides for on-line tandem mass spectrometric analysis of tryptic peptides at the 400-amol level. MS/MS data are searched against similar to 280 000 entries in a nonredundant protein database using SEQUEST. Accurate precursor and product ion mass information readily identifiers primary amino acid sequences differing by:asparagine vs aspartic acid (Delta m = 0.98 Da) and glutamine vs lysine (Delta m = 0.036 Da).
引用
收藏
页码:4266 / 4274
页数:9
相关论文
共 84 条
  • [11] IDENTIFICATION OF A PEPTIDE RECOGNIZED BY 5 MELANOMA-SPECIFIC HUMAN CYTOTOXIC T-CELL LINES
    COX, AL
    SKIPPER, J
    CHEN, Y
    HENDERSON, RA
    DARROW, TL
    SHABANOWITZ, J
    ENGELHARD, VH
    HUNT, DF
    SLINGLUFF, CL
    [J]. SCIENCE, 1994, 264 (5159) : 716 - 719
  • [12] Immunodominance among EBV-derived epitopes restricted by HLA-B27 does not correlate with epitope abundance in EBV-transformed B-lymphoblastoid cell lines
    Crotzer, VL
    Christian, RE
    Brooks, JM
    Shabanowitz, J
    Settlage, RE
    Marto, JA
    White, FM
    Rickinson, AB
    Hunt, DF
    Engelhard, VH
    [J]. JOURNAL OF IMMUNOLOGY, 2000, 164 (12) : 6120 - 6129
  • [13] LOW-FLOW HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY SOLVENT DELIVERY SYSTEM DESIGNED FOR TANDEM CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    DAVIS, MT
    STAHL, DC
    LEE, TD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (07) : 571 - 577
  • [14] A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES
    DAVIS, MT
    STAHL, DC
    HEFTA, SA
    LEE, TD
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (24) : 4549 - 4556
  • [15] Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
    Emmett, MR
    White, FM
    Hendrickson, CL
    Shi, SDH
    Marshall, AG
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (04) : 333 - 340
  • [16] AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE
    ENG, JK
    MCCORMACK, AL
    YATES, JR
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) : 976 - 989
  • [17] Figeys D, 1998, RAPID COMMUN MASS SP, V12, P1435, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1435::AID-RCM349>3.3.CO
  • [18] 2-0
  • [19] Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level
    Figeys, D
    vanOostveen, I
    Ducret, A
    Aebersold, R
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (11) : 1822 - 1828
  • [20] High sensitivity identification of proteins by electrospray ionization tandem mass spectrometry: Initial comparison between an ion trap mass spectrometer and a triple quadrupole mass spectrometer
    Figeys, D
    Aebersold, R
    [J]. ELECTROPHORESIS, 1997, 18 (3-4) : 360 - 368