摘要
Despite the possibility of poorer peak shapes, analysis of pharmaceuticals and other bases using reversed-phase high-performance liquid chromatography (RP-HPLC) at intermediate pH gives useful increases in retention, selectivity and column loading capacity compared with low pH. Retention times of some bases showed anomalous increases with column temperature. Peak shapes for bases improved significantly at elevated temperature (up to 70degreesC), with the weakest bases studied (pK(a) similar to 8) giving greater improvement than the strongest bases (pK(a) similar to 10). In contrast, quaternary ammonium compounds showed reduced retention with increasing column temperature (normal behaviour) and only modest improvements in peak shape. Considering these results, and pK(a) measurements of the bases made using capillary electrophoresis, it appears that increases in retention and improvement in efficiency may be influenced significantly by reduction in the pK(a) of bases with temperature, leading to reduction in protonation. It is less likely that efficiency improvements are due to the speeding up of the kinetics of silanol ion exchange, at least in the temperature range studied here. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 32 条
[21]   Rationalization of retention and overloading behavior of basic compounds in reversed-phase HPLC using low ionic strength buffers suitable for mass spectrometric detection [J].
McCalley, DV .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3404-3410
[22]   Selection of suitable stationary phases and optimum conditions for their application in the separation of basic compounds by reversed-phase HPLC [J].
McCalley, DV .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (3-4) :187-200
[23]   Comparison of conventional microparticulate and a monolithic reversed-phase column for high-efficiency fast liquid chromatography of basic compounds [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :51-64
[24]   Effect of temperature and flow-rate on analysis of basic compounds in high-performance liquid chromatography using a reversed-phase column [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (02) :311-321
[25]   ENTHALPY-ENTROPY COMPENSATION IN REVERSED-PHASE CHROMATOGRAPHY [J].
MELANDER, W ;
CAMPBELL, DE ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT) :215-225
[26]  
NAWROCKI J, 1991, CHROMATOGRAPHIA, V31, P177, DOI 10.1007/BF02274570
[27]  
Neue U.D., 1997, HPLC COLUMNS
[28]   Dependence of reversed-phase retention of ionizable analytes on pH, concentration of organic solvent and silanol activity [J].
Neue, UD ;
Phoebe, CH ;
Tran, K ;
Cheng, YF ;
Lu, ZL .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :49-67
[29]   Hydrophobic and cation exchange mechanisms in the retention of basic compounds in a polymeric column [J].
Ruiz, R ;
Ruiz-Angel, J ;
García-Alvarez-Coque, C ;
Ràfols, C ;
Rosés, M ;
Bosch, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (01) :139-148
[30]   Control of column temperature in reversed-phase liquid chromatography [J].
Wolcott, RG ;
Dolan, JW ;
Snyder, LR ;
Bakalyar, SR ;
Arnold, MA ;
Nichols, JA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :211-230