Helical CT of the pancreas: A comparison of cine display and film-based viewing

被引:13
作者
Bonaldi, VM [1 ]
Bret, PM [1 ]
Atri, M [1 ]
Reinhold, C [1 ]
机构
[1] McGill Univ, Montreal Gen Hosp, Dept Radiol, Quebec City, PQ H3G 1A4, Canada
关键词
D O I
10.2214/ajr.170.2.9456948
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Radiologists must manage a tremendous number of helical CT images daily. Hence, the use of cine display review is increasing. Our aim was to compare cine display of helical CT examinations of the pancreas with conventional film-based viewing. SUBJECTS AND METHODS, Forty-eight consecutive patients undergoing helical CT of the pancreas were prospectively included in the study. Five-millimeter-thick contrast-enhanced helical CT sections of the pancreas were reconstructed in l-mm increments for cine display review and in 5-mm-thick increments for film-based review, Two radiologists reviewed the two sets of data independently. Review of the cine display images was followed by review of the film-based images 2 months later. For both the cine display and the film-based images, reviewers used a four-point scale to grade vascular anatomy (splenic vein and artery, superior mesenteric vein and artery, portal confluence, dorsal pancreatic artery, and gastroduodenal artery); ductal anatomy (common bile duct in its hilar, suprapancreatic, and intrapancreatic portions and pancreatic duct in its caudal, corporeal, and cephalic portions); sharpness of the pancreatic and lesion contours; and overall image quality, RESULTS. The conspicuity of pancreatic contours was graded better on cine display (p = .0035). All venous and arterial landmarks were graded significantly better on cine display, Likewise, visibility of the common bile ducts and pancreatic ducts was scored significantly better with cine display. In three patients, cine display images revealed the pancreatic duct, and the film-based images did not. Although 21 lesions were shown on both sets of images, the lesions were better seen on cine display (p <.005), CONCLUSION, Vascular and ductal anatomy is better delineated on cine images generated from overlapped sections than on conventional film-based images. Lesions are also more sharply delineated on cine display images.
引用
收藏
页码:373 / 376
页数:4
相关论文
共 13 条
[1]   A comparison of two injection protocols using helical and dynamic acquisitions in CT examinations of the pancreas [J].
Bonaldi, VM ;
Bret, PM ;
Atri, M ;
Garcia, P ;
Reinhold, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :49-55
[2]   HELICAL CT OF THE LIVER - VALUE OF AN EARLY HEPATIC ARTERIAL PHASE [J].
BONALDI, VM ;
BRET, PM ;
REINHOLD, C ;
ATRI, M .
RADIOLOGY, 1995, 197 (02) :357-363
[3]   SEQUENTIAL VIEWING OF ABDOMINAL CT IMAGES AT VARYING RATES [J].
GUR, D ;
GOOD, WF ;
OLIVER, JH ;
THAETE, FL ;
BARON, RL ;
FEDERLE, MP ;
CAMPBELL, WL ;
ROSENTHAL, MS .
RADIOLOGY, 1994, 191 (01) :119-122
[4]   DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[5]   A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS [J].
KALENDER, WA ;
POLACIN, A ;
SUSS, C .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :167-176
[6]   DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT [J].
KORMANO, M ;
PARTANEN, K ;
SOIMAKALLIO, S ;
KIVIMAKI, T .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :364-367
[7]   PANCREATIC ADENOCARCINOMA - DESIGNING THE EXAMINATION TO EVALUATE THE CLINICAL QUESTIONS [J].
MEGIBOW, AJ .
RADIOLOGY, 1992, 183 (02) :297-303
[8]   Spiral hydro-CT of the pancreas in the thin-slice method [J].
Richter, GM ;
Simon, C ;
Hoffmann, V ;
DeBernardinis, M ;
Seelos, R ;
Senninger, N ;
Kauffmann, GW .
RADIOLOGE, 1996, 36 (05) :397-405
[9]   3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE [J].
RUBIN, GD ;
DAKE, MD ;
NAPEL, SA ;
MCDONNELL, CH ;
JEFFREY, RB .
RADIOLOGY, 1993, 186 (01) :147-152
[10]   SPIRAL CT OF THE CHEST - COMPARISON OF CINE AND FILM-BASED VIEWING [J].
SELTZER, SE ;
JUDY, PF ;
ADAMS, DF ;
JACOBSON, FL ;
STARK, P ;
KIKINIS, R ;
SWENSSON, RG ;
HOOTON, S ;
HEAD, B ;
FELDMAN, U .
RADIOLOGY, 1995, 197 (01) :73-78