Direct electron detectors for electron microscopy

被引:14
作者
Faruqi, A. R. [1 ]
机构
[1] MRC, Mol Biol Lab, Cambridge CB2 2QH, England
来源
ADVANCES IN IMAGING AND ELECTRON PHYSICS, VOL 145 | 2007年 / 145卷
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
D O I
10.1016/S1076-5670(06)45002-3
中图分类号
O59 [应用物理学];
学科分类号
摘要
Some of the design principles and potential applications of direct-detection detectors for image recording and storage in electron microscopy (EM) are discussed. The major direct-detection detector technologies include hybrid pixel detectors (HPD) and monolithic active pixel sensors (MAPS). HPDs use separate pixellated detector and readout electronics chips and are able to acquire data without adding any noise. The design process of MAPS simplifies the design process and allows the integration of detector and readout on the same chip. Both detectors are based on the latest complementary metal oxide semiconductor (CMOS) design technologies, with significant potential to be used in EM applications. It is also found that the significance of direct-detection detectors have increased with growing application of EM for extensive data collection.
引用
收藏
页码:55 / 93
页数:39
相关论文
共 45 条
[1]   Three-dimensional electron cryo-microscopy as a powerful structural tool in molecular medicine [J].
Auer, M .
JOURNAL OF MOLECULAR MEDICINE-JMM, 2000, 78 (04) :191-202
[2]   Electron tomography of molecules and cells [J].
Baumeister, W ;
Grimm, R ;
Walz, J .
TRENDS IN CELL BIOLOGY, 1999, 9 (02) :81-85
[3]   An interface board for the control and data acquisition of the Medipix2 chip [J].
Bello, DS ;
van Beuzekom, M ;
Jansweijer, P ;
Verkooijen, H ;
Visschers, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :164-170
[4]   Applications and new developments in X-ray materials analysis with MEDIPIX2 [J].
Bethke, K ;
de Vries, R ;
Kogan, V ;
Vasterink, J ;
Verbruggen, R ;
Kidd, P ;
Fewster, P ;
Bethke, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :209-214
[5]   Total dose and displacement damage effects in a radiation-hardened CMOS APS [J].
Bogaerts, J ;
Dierickx, B ;
Meynants, G ;
Uwaerts, D .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (01) :84-90
[6]   A 9 Å single particle reconstruction from CCD captured images on a 200 kV electron cryomicroscope [J].
Booth, CR ;
Jiang, W ;
Baker, ML ;
Zhou, ZH ;
Ludtke, SJ ;
Chiu, W .
JOURNAL OF STRUCTURAL BIOLOGY, 2004, 147 (02) :116-127
[7]   A readout chip for a 64 x 64 pixel matrix with 15-bit single Photon Counting [J].
Campbell, M ;
Heijne, EHM ;
Meddeler, G ;
Pernigotti, E ;
Snoeys, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :751-753
[8]   Preliminary test of Medisoft 4: Control software for the Medipix2 readout chip [J].
Conti, M ;
Maiorino, M ;
Mettivier, G ;
Montesi, MC ;
Russo, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) :869-877
[9]  
Dainty JC., 1974, IMAGE SCI