A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats

被引:19
作者
Uemura, K
Kawada, T
Sugimachi, M
Zheng, C
Kashihara, K
Sato, T
Sunagawa, K
机构
[1] Natl Cardiovasc Ctr, Res Inst, Dept Cardiovasc Dynam, Suita, Osaka 5658565, Japan
[2] Japan Space Forum, Tokyo 1050013, Japan
[3] Org Pharmaceut Safety & Res, Tokyo 1000013, Japan
[4] Kochi Med Sch, Dept Cardiovasc Control, Nankoku, Kochi 7838505, Japan
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2004年 / 287卷 / 06期
关键词
serial reproducibility; volumetric accuracy; dual-frequency method; Bluetooth;
D O I
10.1152/ajpheart.00035.2004
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Using Bluetooth wireless technology, we developed an implantable telemetry system for measurement of the left ventricular pressure-volume relation in conscious, freely moving rats. The telemetry system consisted of a pressure-conductance catheter (1.8-Fr) connected to a small (14-g) fully implantable signal transmitter. To make the system fully telemetric, calibrations such as blood resistivity and parallel conductance were also conducted telemetrically. To estimate blood resistivity, we used four electrodes arranged 0.2 mm apart on the pressure-conductance catheter. To estimate parallel conductance, we used a dual-frequency method. We examined the accuracy of calibrations, stroke volume (SV) measurements, and the reproducibility of the telemetry. The blood resistivity estimated telemetrically agreed with that measured using an ex vivo cuvette method (y = 1.09x - 11.9, r(2) = 0.88, n = 10). Parallel conductance estimated by the dual-frequency (2 and 20 kHz) method correlated well with that measured by a conventional saline injection method (y = 1.59x - 1.77, r(2) = 0.87, n = 13). The telemetric SV closely correlated with the flowmetric SV during inferior vena cava occlusions (y = 0.96x + 7.5, r(2) = 0.96, n = 4). In six conscious rats, differences between the repeated telemetries on different days ( 3 days apart on average) were reasonably small: 13% for end-diastolic volume, 20% for end-systolic volume, 28% for end-diastolic pressure, and 6% for end-systolic pressure. We conclude that the developed telemetry system enables us to estimate the pressure-volume relation with reasonable accuracy and reproducibility in conscious, untethered rats.
引用
收藏
页码:H2906 / H2913
页数:8
相关论文
共 31 条
[1]
SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL [J].
APPLEGATE, RJ ;
CHENG, CP ;
LITTLE, WC .
CIRCULATION, 1990, 81 (02) :638-648
[2]
SERIAL REPRODUCIBILITY OF CONDUCTANCE CATHETER VOLUMETRY OF LEFT-VENTRICLE IN CONSCIOUS DOGS [J].
ASANOI, H ;
ISHIZAKA, S ;
KAMEYAMA, T ;
NOZAWA, T ;
MIYAGI, K ;
SASAYAMA, S .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (03) :H911-H915
[3]
CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[4]
CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[5]
Increased systolic performance with diastolic dysfunction in adult spontaneously hypertensive rats [J].
Cingolani, OH ;
Yang, XP ;
Cavasin, MA ;
Carretero, OA .
HYPERTENSION, 2003, 41 (02) :249-254
[6]
Development of a multifrequency conductance catheter-based system to determine LV function in mice [J].
Feldman, MD ;
Mao, Y ;
Valvano, JW ;
Pearce, JA ;
Freeman, GL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (03) :H1411-H1420
[7]
Progression of heart failure after myocardial infarction in the rat [J].
Francis, J ;
Weiss, RM ;
Wei, SG ;
Johnson, AK ;
Felder, RB .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2001, 281 (05) :R1734-R1745
[8]
ESTIMATING LEFT-VENTRICULAR OFFSET VOLUME USING DUAL-FREQUENCY CONDUCTANCE CATHETERS [J].
GAWNE, TJ ;
GRAY, KS ;
GOLDSTEIN, RE .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (02) :872-876
[9]
Estimation of parallel conductance by dual-frequency conductance catheter in mice [J].
Georgakopoulos, D ;
Kass, DA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (01) :H443-H450
[10]
New technique to measure and track blood resistivity in intracardiac impedance volumetry [J].
Gopakumaran, B ;
Osborn, P ;
Petre, JH ;
Murray, PA .
JOURNAL OF CLINICAL MONITORING, 1997, 13 (06) :363-371