Projection imaging of the right coronary artery with an intravenous injection of contrast agent

被引:7
作者
Green, JD
Schirf, BE
Omary, RA
McCarthy, RM
Carr, JC
Li, D
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
coronary arteries; magnetic resonance angiography; contrast agents; projection imaging;
D O I
10.1002/mrm.20224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast-enhanced (CE) MR angiography of the right coronary artery (RCA) was performed using 2D thick-slice projection imaging with a small (8 mL) intravenous injection of contrast agent in six volunteers. With a tight contrast bolus injection, the RCA was enhanced for a few seconds after the contrast bolus was washed out of the right ventricle. This allowed data to be acquired when only the RCA was enhanced. Using 2D thick-slice magnetization prepared steady-state free precession (SSFP) imaging, background signal was suppressed and a complete data set was acquired in three heartbeats. A mean vessel length of 7.1 +/- 0.9 cm was depicted with a signal-to-noise ratio of 11.8 +/- 0.7 and contrast-to-noise ratio of 6.1 +/- 0.6. Thick-slice 2D projection CE SSFP is a promising method to depict the RCA.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 17 条
[1]   Contrast-enhanced coronary artery imaging using 3D trueFISP [J].
Deshpande, VS ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) :570-577
[2]   Coronary artery imaging using contrast-enhanced 3D segmented EPI [J].
Deshpande, VS ;
Wielopolski, PA ;
Shea, SM ;
Carr, J ;
Zheng, J ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) :676-681
[3]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[4]   Analysis of cardiopulmonary transit times at contrast material-enhanced MR imaging in patients with heart disease [J].
François, CJ ;
Shors, SM ;
Bonow, RO ;
Finn, JP .
RADIOLOGY, 2003, 227 (02) :447-452
[5]   Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography [J].
Goldfarb, JW ;
Edelman, RR .
RADIOLOGY, 1998, 206 (03) :830-834
[6]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[7]   Contrast-enhanced magnetic resonance angiography of the carotid arteries:: Influence of injection rates and volumes on arterial-venous transit time [J].
Herold, T ;
Paetzel, C ;
Völk, M ;
Bachthaler, M ;
Zorger, N ;
Feuerbach, S ;
Strotzer, M ;
Lenhart, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (02) :65-72
[8]   The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. [J].
Kim, RJ ;
Wu, E ;
Rafael, A ;
Chen, EL ;
Parker, MA ;
Simonetti, O ;
Klocke, FJ ;
Bonow, RO ;
Judd, RM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) :1445-1453
[9]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869
[10]   Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography [J].
Li, DB ;
Carr, JC ;
Shea, SM ;
Zheng, J ;
Deshpande, VS ;
Wielopolski, PA ;
Finn, JP .
RADIOLOGY, 2001, 219 (01) :270-277