Breaking the spherical and chromatic aberration barrier in transmission electron microscopy

被引:83
作者
Freitag, B [1 ]
Kujawa, S [1 ]
Mul, PM [1 ]
Ringnalda, J [1 ]
Tiemeijer, PC [1 ]
机构
[1] FEI Electron Opt, NL-5600 KA Eindhoven, Netherlands
关键词
aberration correction; monochromator; high resolution TEM;
D O I
10.1016/j.ultramic.2004.09.013
中图分类号
TH742 [显微镜];
学科分类号
摘要
Since the invention of transmission electron microscopy (TEM) in 1932 (Z. Physik 78 (1932) 318) engineering improvements have advanced system resolutions to levels that are now limited only by the two fundamental aberrations of electron lenses; spherical and chromatic aberration (Z. Phys. 101 (1936) 593). Since both aberrations scale with the dimensions of the lens, research resolution requirements are pushing the designs to lenses with only a few mm space in the pole-piece gap for the specimen. This is in conflict with the demand for more and more space at the specimen. necessary in order to enable novel techniques in TEM, such as He-cooled cryo electron microscopy. 3D-reconstruction through tomography (Science 302 (2003) 1396) TEM in gaseous environments, or in situ experiments (Nature 421 (2004) 426). All these techniques will only be able to achieve Angstrom resolution when (he aberration barriers have been overcome. The spherical aberration barrier has recently been broken by introducing spherical aberration correctors (Nature 392 (1998) 392 418 (2002) 617), but the correction of the remaining chromatic aberrations have proved to be too difficult for the present state of technology (Optik 57 (1980) 73). Here we present an alternative and successful method to eliminate the chromatic blur, which consists of monochromating the TEM beam (Inst. Phys. Conf. Ser. 161 (1999) 191). We show directly interpretable resolutions well below 1 Angstrom for the first time. which is significantly better than any TEM operating at 200 KV has reached before. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 14 条
  • [1] Sub-angstrom resolution using aberration corrected electron optics
    Batson, PE
    Dellby, N
    Krivanek, OL
    [J]. NATURE, 2002, 418 (6898) : 617 - 620
  • [2] BERNHARD W, 1980, OPTIK, V57, P73
  • [3] PHASE RETRIEVAL THROUGH FOCUS VARIATION FOR ULTRA-RESOLUTION IN FIELD-EMISSION TRANSMISSION ELECTRON-MICROSCOPY
    COENE, W
    JANSSEN, G
    DEBEECK, MO
    VANDYCK, D
    [J]. PHYSICAL REVIEW LETTERS, 1992, 69 (26) : 3743 - 3746
  • [4] HOLOGRAPHIC MEASUREMENT OF THE WAVE-ABERRATION OF AN ELECTRON-MICROSCOPE BY MEANS OF THE PHASES IN THE FOURIER SPECTRUM
    FU, Q
    LICHTE, H
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1995, 179 : 112 - 118
  • [5] Three-dimensional structure of herpes simplex virus from cryo-electron tomography
    Grünewald, K
    Desai, P
    Winkler, DC
    Heymann, JB
    Belnap, DM
    Baumeister, W
    Steven, AC
    [J]. SCIENCE, 2003, 302 (5649) : 1396 - 1398
  • [6] Electron microscopy image enhanced
    Haider, M
    Uhlemann, S
    Schwan, E
    Rose, H
    Kabius, B
    Urban, K
    [J]. NATURE, 1998, 392 (6678) : 768 - 769
  • [7] Atomic-scale imaging of carbon nanofibre growth
    Helveg, S
    López-Cartes, C
    Sehested, J
    Hansen, PL
    Clausen, BS
    Rostrup-Nielsen, JR
    Abild-Pedersen, F
    Norskov, JK
    [J]. NATURE, 2004, 427 (6973) : 426 - 429
  • [8] Atomic-resolution imaging of oxygen in perovskite ceramics
    Jia, CL
    Lentzen, M
    Urban, K
    [J]. SCIENCE, 2003, 299 (5608) : 870 - 873
  • [9] High-resolution imaging with an aberration-corrected transmission electron microscope
    Lentzen, M
    Jahnen, B
    Jia, CL
    Thust, A
    Tillmann, K
    Urban, K
    [J]. ULTRAMICROSCOPY, 2002, 92 (3-4) : 233 - 242
  • [10] ROSE H, 1971, OPTIK, V33, P1