Sigmoidal curve-fitting redefines quantitative real-time PCR with the prospective of developing automated high-throughput applications

被引:154
作者
Rutledge, RG [1 ]
机构
[1] Nat Resources Canada, Ste Foy, PQ G1V 4C7, Canada
关键词
D O I
10.1093/nar/gnh177
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative real-time PCR has revolutionized many aspects of genetic research, biomedical diagnostics and pathogen detection. Nevertheless, the full potential of this technology has yet to be realized, primarily due to the limitations of the threshold-based methodologies that are currently used for quantitative analysis. Prone to errors caused by variations in reaction preparation and amplification conditions, these approaches necessitate construction of standard curves for each target sequence, significantly limiting the development of high-throughput applications that demand substantive levels of reliability and automation. In this study, an alternative approach based upon fitting of fluorescence data to a four-parametric sigmoid function is shown to dramatically increase both the utility and reliability of quantitative real-time PCR. By mathematically modeling individual amplification reactions, quantification can be achieved without the use of standard curves and without prior knowledge of amplification efficiency. Combined with provision of quantitative scale via optical calibration, sigmoidal curve-fitting could confer the capability for fully automated quantification of nucleic acids with unparalleled accuracy and reliability.
引用
收藏
页数:8
相关论文
共 25 条
  • [11] Analysis of relative gene expression data using real-time quantitative PCR and the 2-ΔΔCT method
    Livak, KJ
    Schmittgen, TD
    [J]. METHODS, 2001, 25 (04) : 402 - 408
  • [12] Real-time PCR in virology
    Mackay, IM
    Arden, KE
    Nitsche, A
    [J]. NUCLEIC ACIDS RESEARCH, 2002, 30 (06) : 1292 - 1305
  • [13] Mazzanti M. Bonvini, 1998, SENIGALLIA, P129
  • [14] A novel method to compensate for different amplification efficiencies between patient DNA samples in quantitative real-time PCR
    Meijerink, J
    Mandigers, C
    van de Locht, L
    Tönnissen, E
    Goodsaid, F
    Raemaekers, J
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2001, 3 (02) : 55 - 61
  • [15] Morrison TB, 1998, BIOTECHNIQUES, V24, P954
  • [16] Quantitation of viral load using real-time amplification techniques
    Niesters, HGM
    [J]. METHODS, 2001, 25 (04) : 419 - 429
  • [17] Experimental validation of novel and conventional approaches to quantitative real-time PCR data analysis
    Peirson, SN
    Butler, JN
    Foster, RG
    [J]. NUCLEIC ACIDS RESEARCH, 2003, 31 (14) : e73
  • [18] Validities of mRNA quantification using recombinant RNA and recombinant DNA external calibration curves in real-time RT-PCR
    Pfaffl, MW
    Hageleit, M
    [J]. BIOTECHNOLOGY LETTERS, 2001, 23 (04) : 275 - 282
  • [19] A new mathematical model for relative quantification in real-time RT-PCR
    Pfaffl, MW
    [J]. NUCLEIC ACIDS RESEARCH, 2001, 29 (09) : E45
  • [20] Rasmussen R., 2001, Rapid cycle real-time PCR, P21, DOI [10.1007/978-3-642-59524-0_3, DOI 10.1007/978-3-642-59524-0_3]