Study on a compact silica gel-water adsorption chiller without vacuum valves: Design and experimental study

被引:89
作者
Chen, C. J. [1 ]
Wang, R. Z. [1 ]
Xia, Z. Z. [1 ]
Kiplagat, J. K. [1 ]
Lu, Z. S. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
Refrigeration; Adsorption chiller; Water; Silica gel; Heat and mass recovery; PERFORMANCE IMPROVEMENT; MASS RECOVERY; HEAT-SOURCE; PART I; SYSTEM; EVAPORATION; BED;
D O I
10.1016/j.apenergy.2010.03.022
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A compact silica gel-water adsorption chiller without vacuum valves was manufactured and experimentally studied This chiller contains two adsorption/desorption chambers and one chilled water tank Each adsorption/desorption chamber consists of one adsorber, one condenser and one evaporator The chilled water tank is adopted to mitigate the variation of the chilled water outlet temperature A mass recovery-like process, which is a heat recovery process between the two evaporators, was carried out in this chiller A novel heat recovery process was also fulfilled after the mass recovery-like process to improve the coefficient of performance (COP). The cooling power and COP were 960 kW and 049 respectively when the average hot water inlet temperature, cooling water inlet temperature, and chilled water outlet temperature were 82 0, 31.6 and 12.3 degrees C. respectively. (C) 2010 Elsevier Ltd All rights reserved.
引用
收藏
页码:2673 / 2681
页数:9
相关论文
共 22 条
[1]   A family of new working materials for solid sorption air conditioning systems [J].
Aristov, YI ;
Restuccia, G ;
Cacciola, G ;
Parmon, VN .
APPLIED THERMAL ENGINEERING, 2002, 22 (02) :191-204
[2]   Experimental study of a solid adsorption cooling system using flat-tube heat exchangers as adsorption bed [J].
Chang, W.-S. ;
Wang, C.-C. ;
Shieh, C.-C. .
APPLIED THERMAL ENGINEERING, 2007, 27 (13) :2195-2199
[3]   Theoretical and experimental study on characteristics of a novel silica gel-water chiller under the conditions of variable heat source temperature [J].
Di, J. ;
Wu, J. Y. ;
Xia, Z. Z. ;
Wang, R. Z. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (03) :515-526
[4]   Enhancement of heat and mass transfer in silica-expanded graphite composite blocks for adsorption heat pumps: Part I. Characterization of the composite blocks [J].
Eun, TH ;
Song, HK ;
Han, JH ;
Lee, KH ;
Kim, JN .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (01) :64-73
[5]   Thermal conductivity of selective water sorbents under the working conditions of a sorption chiller [J].
Freni, A ;
Tokarev, MM ;
Restuccia, G ;
Okunev, AG ;
Aristov, YI .
APPLIED THERMAL ENGINEERING, 2002, 22 (14) :1631-1642
[6]   Solar assisted air conditioning of buildings - an overview [J].
Henning, Hans-Martin .
APPLIED THERMAL ENGINEERING, 2007, 27 (10) :1734-1749
[7]   Theoretical research of a silica gel-water adsorption chiller in a micro combined cooling, heating and power (CCHP) system [J].
Li, S. ;
Wu, J. Y. .
APPLIED ENERGY, 2009, 86 (06) :958-967
[8]   Experimental study on a continuous adsorption water chiller with novel design [J].
Liu, YL ;
Wang, RZ ;
Xia, ZZ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (02) :218-230
[9]   Experimental study on performance improvement of a four-bed adsorption chiller by using heat, and mass recovery [J].
Ng, Kim Choon ;
Wang, Xiaolin ;
Lim, Yee Sern ;
Saha, Bidyut Baran ;
Chakarborty, Anutosh ;
Koyama, Shigeru ;
Akisawa, Atsushi ;
Kashiwagi, Takao .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (19-20) :3343-3348
[10]   A new generation cooling device employing CaCl2-in-silica gel-water system [J].
Saha, Bidyut Baran ;
Chakraborty, Anutosh ;
Koyama, Shigeru ;
Aristov, Yu I. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (1-2) :516-524