摘要
While recent reports have advocated the use of magnetic resonance imaging (MRI) to detect the effects of neuronal currents associated with human brain activity, only preliminary experimental data have been presented so far to demonstrate the feasibility of the method. Furthermore, it has not been adequately demonstrated that (1) MRI can separate neuronal current (NC) effects from other effects such as blood oxygen level-dependent (BOLD) contrast; (2) MRI has adequate sensitivity to detect NCs in vivo. In this work, we introduce a method that can separate slow (e.g., BOLD) processes from potential rapid (e.g., NC) processes and apply this method to investigate whether MRI allows detection of an NC response to a visual stimulus. MRI studies (n = 8) at 3.0 T using a sensitive multichannel detector showed insignificant effects related to NCs (averaged t < 0.05), in the presence of a highly significant BOLD signal Q = 6.15 +/- 0.90). In contrast, magnetoencephalography (MEG) experiments performed under similar conditions on the same subjects showed highly significant electrical activity Q = 7.90 +/- 2.28). It is concluded that, under the conditions used in this study, the sensitivity of MRI to detect evoked responses through NCs is at least an order of magnitude below that of BOLD-based functional MRI (fMRI) or MEG and too low to be practically useful. Published by Elsevier Inc.
引用
收藏
页码:1059 / 1067
页数:9
相关论文
共 27 条
[1]   Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic fields changes [J].
Bodurka, J ;
Bandettini, PA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1052-1058
[2]   Scalable multichannel MRI data acquisition system [J].
Bodurka, J ;
Ledden, PJ ;
van Gelderen, P ;
Chu, RX ;
de Zwart, JA ;
Morris, D ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :165-171
[3]   IMAGE-RECONSTRUCTION FOR ECHO PLANAR IMAGING WITH NONEQUIDISTANT KAPPA-SPACE SAMPLING [J].
BRUDER, H ;
FISCHER, H ;
REINFELDER, HE ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :311-323
[4]   Efficient design of event-related fMRI experiments using M-sequences [J].
Buracas, GT ;
Boynton, GM .
NEUROIMAGE, 2002, 16 (03) :801-813
[5]   Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla [J].
de Zwart, JA ;
Ledden, PJ ;
van Gelderen, P ;
Bodurka, J ;
Chu, RX ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :22-26
[6]   Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1011-1020
[7]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[8]   Steady state effects in fast gradient echo magnetic resonance imaging [J].
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) :559-568
[9]   EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidth [J].
Fera, F ;
Yongbi, MN ;
van Gelderen, P ;
Frank, JA ;
Mattay, VS ;
Duyn, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) :19-26
[10]   THE REPRESENTATION OF THE VISUAL-FIELD IN HUMAN STRIATE CORTEX - A REVISION OF THE CLASSIC HOLMES MAP [J].
HORTON, JC ;
HOYT, WF .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (06) :816-824