Intensity inhomogeneity (IIH) is often encountered in MR imaging, and a number of techniques have been devised to correct this artifact. This paper attempts to review some of the recent developments in the mathematical modeling of IIH field. Low-frequency models are widely used, but they tend to corrupt the low-frequency components of the tissue. Hypersurface models and statistical models can be adaptive to the image and generally more stable, but they are also generally more complex and consume more computer memory and CPU time. They are often formulated together with image segmentation within one framework and the overall performance is highly dependent on the segmentation process. Beside these three popular models, this paper also summarizes other techniques based on different principles. In addition, the issue of quantitative evaluation and comparative study are discussed. Copyright (C) 2006 Zujun Hou.
引用
收藏
页数:11
相关论文
共 101 条
[31]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[32]  
Gonzalez R.C., 1993, DIGITAL IMAGE PROCES
[33]   Estimating the bias field of MR images [J].
Guillemaud, R ;
Brady, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (03) :238-251
[34]   A multi-scale method for automatic correction of intensity non-uniformity in MR images [J].
Han, C ;
Hatsukami, TS ;
Yuan, C .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :428-436
[35]   SOURCES OF T1 VARIANCE IN NORMAL HUMAN WHITE MATTER [J].
HARVEY, I ;
TOFTS, PS ;
MORRIS, JK ;
WICKS, DAG ;
RON, MA .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :53-59
[36]  
HASELGROVE J, 1986, Magnetic Resonance Imaging, V4, P469, DOI 10.1016/0730-725X(86)90024-X
[37]   VOLUME IMAGING WITH MR PHASED-ARRAYS [J].
HAYES, CE ;
HATTES, N ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :309-319
[38]   Markov random field segmentation of brain MR images [J].
Held, K ;
Kops, ER ;
Krause, BJ ;
Wells, WM ;
Kikinis, R ;
Muller-Gartner, HW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :878-886
[39]  
Hou Z., 2002, PRELIMINARY SEGMENTA
[40]   Inhomogeneity correction using an estimated linear field map [J].
Irarrazabal, P ;
Meyer, CH ;
Nishimura, DG ;
Macovski, A .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :278-282