COMPARISON OF THE KEELER PULSAIR-2000 NONCONTACT TONOMETER WITH GOLDMANN APPLANATION

被引:24
作者
MOSELEY, MJ
THOMPSON, JR
DEUTSCH, J
MISSON, GP
NAYLOR, G
TANYEE, A
TAYLOR, RH
FIELDER, AR
机构
[1] UNIV BIRMINGHAM,DEPT OPHTHALMOL,BIRMINGHAM B15 2TT,W MIDLANDS,ENGLAND
[2] UNIV LEICESTER,LEICESTER ROYAL INFIRM,DEPT OPHTHALMOL,LEICESTER LE1 7RH,ENGLAND
关键词
GOLDMANN APPLANATION TONOMETRY; INTRAOCULAR PRESSURE; NONCONTACT TONOMETRY; PULSAIR-2000; TONOMETRY;
D O I
10.1038/eye.1993.26
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The Pulsair 2000 non-contact tonometer (Keeler Ltd, UK) is compared with the Goldmann applanation tonometer. Data from 80 eyes were acquired by four experienced observers. A linear regression analysis showed the relationship between the instruments to be: Pulsair=0.66 + 0.95 Goldmann. Individual components of variation were analysed by analysis of variance which indicated a significant variation in the slope of the regression equation due to observers (p=0.02) but not to the order in which topical anaesthesia was administered. Differences between two Pulsair instruments were of marginal significance (p=0.07). The intercept of the regression equation was unaffected by any of the components of variation. Seventy-nine per cent of averaged intraocular pressure measurements obtained with the Pulsair 2000 fell on or within +/-3 mmHg of those measured with the Goldmann tonometer. It is concluded that the Pulsair 2000 can provide clinically useful measurements of intraocular pressure.
引用
收藏
页码:127 / 130
页数:4
相关论文
共 36 条
[1]   EVALUATION OF THE TONO-PEN AND THE PULSAIR TONOMETERS [J].
ARMSTRONG, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (06) :716-720
[2]   UBER DEN SPONTANEN DRUCKABFALL BEI APPLANATIONSTONOMETRIE [J].
BECHRAKIS, E .
OPHTHALMOLOGICA, 1966, 151 (05) :604-+
[3]   EVALUATION OF KEELER PULSAIR NONCONTACT TONOMETRY - RELIABILITY AND REPRODUCIBILITY [J].
BONOMI, L ;
BARAVELLI, S ;
COBBE, C ;
TOMAZZOLI, L .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1991, 229 (03) :210-212
[4]   THE KEELER PULSAIR AIR IMPULSE TONOMETER - COMPARISON WITH THE PERKINS HAND-HELD APPLANATION TONOMETER FOR PERI-OPERATIVE MEASUREMENT OF INTRAOCULAR-PRESSURE [J].
BRICKER, SRW ;
MCGALLIARD, JN ;
MOSTAFA, SM .
ANAESTHESIA, 1990, 45 (01) :36-39
[5]   MICROAEROSOL FORMATION IN NONCONTACT AIR-PUFF TONOMETRY [J].
BRITT, JM ;
CLIFTON, BC ;
BARNEBEY, HS ;
MILLS, RP .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (02) :225-228
[6]   NONCONTACT TONOMETRY IN CHILDREN [J].
BUSCEMI, M ;
CAPOFERRI, C ;
GARAVAGLIA, A ;
NASSIVERA, C ;
NUCCI, P .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (06) :461-464
[7]  
CHATTERJEE S, 1974, REGRESSION ANAL EXAM
[8]  
Choi W J, 1990, Korean J Ophthalmol, V4, P30
[9]  
CLIMENHAGA H, 1989, CAN J OPHTHALMOL, V24, P7
[10]  
DRAEGER J, 1989, Eye (London), V3, P738