VARIABLES ASSOCIATED WITH THE DEVELOPMENT OF COMPLICATIONS FROM RADIOSURGERY OF INTRACRANIAL TUMORS

被引:184
作者
NEDZI, LA
KOOY, H
ALEXANDER, E
GELMAN, RS
LOEFFLER, JS
机构
[1] HARVARD UNIV, SCH MED, STEREOTACT RADIOSURG PROGRAM, BOSTON, MA 02115 USA
[2] HARVARD UNIV, CHILDRENS HOSP, BRIGHAM & WOMENS HOSP, DIV NEUROSURG, BOSTON, MA 02115 USA
[3] HARVARD UNIV, SCH MED, DANA FARBER CANC INST, DIV BIOSTAT, BOSTON, MA 02115 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 21卷 / 03期
关键词
STEREOTAXIC RADIOSURGERY; INTRACRANIAL TUMORS; COMPLICATIONS; DOSE VOLUME HISTOGRAM; INHOMOGENEITY; LOGISTIC MODEL;
D O I
10.1016/0360-3016(91)90675-T
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Between 5/21/86 and 11/1/89, we treated 64 recurrent or inoperable intracranial tumors in 60 patients (40 primary, 24 metastatic) with stereotactic radiosurgery using a modified 6 MeV linear accelerator at the Joint Center for Radiation Therapy. Patients were followed until death or 1/1/90. The median follow-up was 8 months (2-43 months). Fourteen patients experienced complications from 12 hours to 7 months (median 3 months, but only two patients more than 4 months) following radiosurgery. To determine variables related to complication, we calculated integral dose-volume histograms for 61/64 lesions and the surrounding CT-defined normal tissue. We excluded 16 lesions in 15 patients for follow-up < 4 months (12 patients) or insufficient treatment information (3 patients). The variables for which higher values were associated with significantly more toxicity in a univariate score test were: a) tumor dose inhomogeneity (p < 0.00001), b) maximum tumor dose (p = 0.00002), c) number of isocenters (p = 0.00002), d) maximum normal tissue dose (p = 0.00005) and e) tumor volume (p = 0.0001). These variables were all highly correlated with tumor dose inhomogeneity (coefficients of rank correlation 0.75 4.81). Tumor dose inhomogeneity had a much higher loglikelihood in a logistic model than any other single variable and a higher loglikelihood than any other two variables combined. None of the 21 patients with metastatic lesions experienced a complication. When we excluded the metastatic lesions, the above five variables remained significant in univariate tests. The mean tumor dose, number of treatment arcs, total degrees of are, tumor location, previous radiotherapy, tumor geometry, pretreatment performance status, collimator size, and age were not significantly associated with toxicity. We conclude that radiosurgery of intracranial tumors is associated with a low risk of complications for lesions < l0cc treated with a single isocenter to maximum tumor doses < 25 Gy with tumor dose inhomogeneity < 10 Gy, but that treatment of larger lesions will require new treatment strategies which reduce the tumor dose inhomogeneity associated with multiple isocenter treatments.
引用
收藏
页码:591 / 599
页数:9
相关论文
共 30 条
  • [21] PAGANO M, 1985, USER MANUAL DATA ANA
  • [22] COMPARISON OF DIFFERENT RADIATION TYPES AND IRRADIATION GEOMETRIES IN STEREOTACTIC RADIOSURGERY
    PHILLIPS, MH
    FRANKEL, KA
    LYMAN, JT
    FABRIKANT, JI
    LEVY, RP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01): : 211 - 220
  • [23] LOW-GRADE ASTROCYTOMAS - TREATMENT WITH UNCONVENTIONALLY FRACTIONATED EXTERNAL BEAM STEREOTACTIC RADIATION-THERAPY
    POZZA, F
    COLOMBO, F
    CHIEREGO, G
    AVANZO, RC
    MARCHETTI, C
    BENEDETTI, A
    CASENTINI, L
    DANIELI, D
    [J]. RADIOLOGY, 1989, 171 (02) : 565 - 569
  • [24] RADIOSURGERY FOR ARTERIOVENOUS-MALFORMATIONS OF THE BRAIN USING A STANDARD LINEAR-ACCELERATOR - RATIONALE AND TECHNIQUE
    SAUNDERS, WM
    WINSTON, KR
    SIDDON, RL
    SVENSSON, GH
    KIJEWSKI, PK
    RICE, RK
    HANSEN, JL
    BARTH, NH
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (02): : 441 - 447
  • [25] MODELS IN RADIOTHERAPY - VOLUME EFFECTS
    SCHULTHEISS, TE
    ORTON, CG
    PECK, RA
    [J]. MEDICAL PHYSICS, 1983, 10 (04) : 410 - 415
  • [26] THERAPEUTIC IRRADIATION AND BRAIN INJURY
    SHELINE, GE
    WARA, WM
    SMITH, V
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1980, 6 (09): : 1215 - 1228
  • [27] STEREOTAXIC HEAVY-CHARGED-PARTICLE BRAGG-PEAK RADIATION FOR INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS
    STEINBERG, GK
    FABRIKANT, JI
    MARKS, MP
    LEVY, RP
    FRANKEL, KA
    PHILLIPS, MH
    SHUER, LM
    SILVERBERG, GD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (02) : 96 - 101
  • [28] STEREOTAXIC PERCUTANEOUS SINGLE DOSE IRRADIATION OF BRAIN METASTASES WITH A LINEAR-ACCELERATOR
    STURM, V
    KOBER, B
    HOVER, KH
    SCHLEGEL, W
    BOESECKE, R
    PASTYR, O
    HARTMANN, GH
    SCHABBERT, S
    ZUMWINKEL, K
    KUNZE, S
    LORENZ, WJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (02): : 279 - 282
  • [29] WHITE KT, 1981, MAYO CLIN PROC, V56, P424
  • [30] PHYSICS OF GAMMA-KNIFE APPROACH ON CONVERGENT BEAMS IN STEREOTAXIC RADIOSURGERY
    WU, A
    LINDNER, G
    MAITZ, AH
    KALEND, AM
    LUNSFORD, LD
    FLICKINGER, JC
    BLOOMER, WD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (04): : 941 - 949