STRENGTH RETENTION OF SELF-REINFORCED POLY-L-LACTIDE SCREWS AND PLATES - AN INVIVO AND INVITRO STUDY

被引:61
作者
SUURONEN, R
POHJONEN, T
TAURIO, R
TORMALA, P
WESSMAN, L
RONKKO, K
VAINIONPAA, S
机构
[1] TAMPERE UNIV,INST PLAST TECHNOL,BIOMAT LAB,SF-33101 TAMPERE,FINLAND
[2] COLL VET MED,DEPT SURG,SF-00580 HELSINKI,FINLAND
[3] HELSINKI UNIV,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,SF-00260 HELSINKI,FINLAND
关键词
D O I
10.1007/BF00701239
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Self-reinforced poly-L-lactide (SR-PLLA) screws and multilayer plates were studied for their initial mechanical shear and/or tensile strength and strength retention in vivo and in vitro up to 48 weeks. The plates were studied in vitro up to 68 weeks. The loss of strength was faster in vivo than in vitro. The screws retained more than half of their initial shear strength up to 12 weeks in vivo and over 24 weeks in vitro. By 48 weeks they had lost nearly all of their mechanical strength in both groups. The plates retained over 54% of their initial tensile and 71% of shear strength up to 24 weeks in vivo. The shear strength did not particularly diminish up to 52 weeks of follow-up in vitro whereas the tensile strength was slightly decreased after 36 weeks. After this follow-up time the loss of strength was more rapid and by 68 weeks the shear strength had decreased to 17% and the tensile strength to 0%.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 43 条
[31]  
ROKKANEN P, 1985, LANCET, V1, P1422
[32]   INFLUENCE OF RESORBABLE POLY(L-LACTIDE)BONE PLATES AND SCREWS ON THE DOSE DISTRIBUTIONS OF RADIOTHERAPY BEAMS [J].
ROZEMA, FR ;
LEVENDAG, PC ;
BOS, RRM ;
BOERING, G ;
PENNINGS, AJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 19 (06) :374-376
[33]   POLY(L-LACTIDE) IMPLANTS IN REPAIR OF DEFECTS OF THE ORBITAL FLOOR - AN ANIMAL STUDY [J].
ROZEMA, FR ;
BOS, RRM ;
PENNINGS, AJ ;
JANSEN, HWB .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 48 (12) :1305-1309
[34]  
SALTHOUSE TN, 1976, SURG GYNECOL OBSTET, V42, P544
[35]   COMPARISON OF ABSORBABLE SELF-REINFORCED POLY-L-LACTIDE SCREWS AND METALLIC SCREWS IN THE FIXATION OF MANDIBULAR CONDYLE OSTEOTOMIES - AN EXPERIMENTAL-STUDY IN SHEEP [J].
SUURONEN, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (09) :989-995
[36]   COMPARISON OF ABSORBABLE SELF-REINFORCED MULTILAYER POLY-L-LACTIDE AND METALLIC PLATES FOR THE FIXATION OF MANDIBULAR BODY OSTEOTOMIES - AN EXPERIMENTAL-STUDY IN SHEEP [J].
SUURONEN, R ;
POHJONEN, T ;
TECH, L ;
VASENIUS, J ;
VAINIONPAA, S .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (03) :255-262
[37]  
SUURONEN R, 1992, Clinical Materials, V9, P77, DOI 10.1016/0267-6605(92)90052-U
[38]  
SUURONEN R, 1992, MATER MED, V3, P88
[39]  
TORMALA P, 1988, Patent No. 4743267
[40]  
TORMALA P, IN PRESS BIOMEDICAL