RAMAN-SPECTROSCOPIC MEASUREMENT OF SPATIAL AND TEMPORAL TEMPERATURE-GRADIENTS IN OPERATING ELECTROPHORESIS CAPILLARIES

被引:85
作者
LIU, KLK [1 ]
DAVIS, KL [1 ]
MORRIS, MD [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
D O I
10.1021/ac00093a033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Steady-state and transient intracapillary temperature gradients are measured by Raman microthermometry during capillary zone electrophoresis. The axial temperature gradient away from a heat sink extends for several millimeters, depending upon the contact of the capillary and heat sink. In free-air convection, small radial gradients, 2-4 degrees C from the center of the lumen to the wall, are observed at 0.85 kW/cm(3). The temperature profile is adequately described by a parabola. With forced cooling, the center-wall temperature difference is less than 1 degrees C. The time to steady-state temperature after power-on is found to be 20 s. The measurements are compared to the results of heat transport calculations.
引用
收藏
页码:3744 / 3750
页数:7
相关论文
共 27 条
[1]  
ARPACI VS, 1984, CONDUCTION HEAT TRAN
[2]   AXIAL TRANSMISSIVE F/1.8 IMAGING RAMAN SPECTROGRAPH WITH VOLUME-PHASE HOLOGRAPHIC FILTER AND GRATING [J].
BATTEY, DE ;
SLATER, JB ;
WLUDYKA, R ;
OWEN, H ;
PALLISTER, DM ;
MORRIS, MD .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1913-1919
[3]   UNSTEADY HEAT-TRANSFER IN CAPILLARY ZONE ELECTROPHORESIS .2. COMPUTER-SIMULATIONS [J].
BELLO, MS ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1992, 606 (01) :103-111
[4]   UNSTEADY HEAT-TRANSFER IN CAPILLARY ZONE ELECTROPHORESIS .1. A MATHEMATICAL-MODEL [J].
BELLO, MS ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY, 1992, 606 (01) :95-102
[5]   COMPUTER-ASSISTED DETERMINATION OF THE INNER TEMPERATURE AND PEAK CORRECTION FOR CAPILLARY ELECTROPHORESIS [J].
BELLO, MS ;
LEVIN, EI ;
RIGHETTI, PG .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :329-336
[6]   PREDICTION OF CURRENT VOLTAGE DEPENDENCE AND ELECTROCHEMICAL CALIBRATION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
BELLO, MS ;
CHIARI, M ;
NESI, M ;
RIGHETTI, PG ;
SARACCHI, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 625 (02) :323-330
[7]  
BOCEK P, 1977, COLLECT CZECH CHEM C, V42, P3382
[8]   ELECTROPHORETIC THERMAL THEORY .2. STEADY-STATE RADIAL TEMPERATURE-GRADIENTS IN CIRCULAR SECTION COLUMNS [J].
BROWN, JF ;
HINCKLEY, JON .
JOURNAL OF CHROMATOGRAPHY, 1975, 109 (02) :218-224
[9]   INFLUENCE OF COLUMN TEMPERATURE AND PHYSICOCHEMICAL PROPERTIES ON THE ELECTROPHORETIC BEHAVIOR OF POLYGLYCINE PEPTIDES IN FREE-SOLUTION CAPILLARY ELECTROPHORESIS [J].
CHEN, N ;
WANG, L ;
ZHANG, YK .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :175-182
[10]   RADIAL TEMPERATURE DISTRIBUTION IN ISOTACHOPHORESIS COLUMNS OF CIRCULAR CROSS-SECTION [J].
COXON, M ;
BINDER, MJ .
JOURNAL OF CHROMATOGRAPHY, 1974, 101 (01) :1-16