SIMULTANEOUS MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION, THORACIC ELECTRICAL BIOIMPEDANCE AND DOPPLER ULTRASOUND

被引:38
作者
CASTOR, G [1 ]
KLOCKE, RK [1 ]
STOLL, M [1 ]
HELMS, J [1 ]
NIEDERMARK, I [1 ]
机构
[1] UNIV SAARLAND,DEPT ANAESTHESIOL,D-66424 HOMBURG,GERMANY
关键词
MEASUREMENT TECHNIQUES; CARDIAC OUTPUT;
D O I
10.1093/bja/72.1.133
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
To evaluate the accuracy of two non-invasive techniques for cardiac output (CO) measurement, we have measured CO simultaneously by thoracic electrical bioimpedance (TEB), pulsed Doppler ultrasound (DU) and standard thermodilution methods (TD) under different clinical conditions. Measurements were made in 10 patients: (I) during steady state anaesthesia with controlled IPPV ventilation (n = 131), spread over the entire ventilatory cycle; (II) during apnoea (n = 56); (III) during spontaneous breathing (n = 152) in the intensive care unit. Mean (so) cardiac output values were: (I) COTD 3.5 (1.0) litre min(-1), COTEB 3.4 (0.7) litre min(-1), CODU 2.8 (0.7) litre min(-1) (II) COTD 3.6 (0.6) litre min(-1), COTEB 3.5 (0.4) litre min(-1), CODU 2.9 (0.7) litre min(-1); (III) COTD 7.7 (1.5) litre min(-1), COTEB 7.6 (1.9) litre min(-1), CODU 5.2 (1.4) litre min(-1). The mean percentage deviation of TEB from TD ranged from -2.2% to 1.4% and that of DU from TD was from -16% to -32%. There were no statistically significant differences between TD and TEB, but TD and DU differed significantly during IPPV, apnoea and spontaneous ventilation (P < 0.0001).
引用
收藏
页码:133 / 138
页数:6
相关论文
共 40 条
[31]   ACCURACY OF DETERMINATION OF CHANGES IN CARDIAC-OUTPUT BY TRANS-CUTANEOUS CONTINUOUS-WAVE DOPPLER COMPUTER [J].
ROSE, JS ;
NANNA, M ;
RAHIMTOOLA, SH ;
ELKAYAM, U ;
MCKAY, C ;
CHANDRARATNA, PAN .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (08) :1099-1101
[32]  
RUSHMER RF, 1966, ANESTH ANAL CURR RES, V45, P383
[33]   CARDIOVASCULAR CHANGES FROM EXPIRATION TO INSPIRATION DURING IPPV [J].
SANTAMORE, WP ;
HECKMAN, JL ;
BOVE, AA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 245 (02) :H307-H312
[34]   SOME ASPECTS TO PULSATION ERROR IN BLOOD-FLOW CALCULATIONS BY INDICATOR-DILUTION TECHNIQUES [J].
SCHEUERLEESER, M ;
MORGUET, A ;
REUL, H ;
IRNICH, W .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (02) :118-123
[35]   SIMULTANEOUS INTRAOPERATIVE MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION AND TRANSTRACHEAL DOPPLER [J].
SIEGEL, LC ;
FITZGERALD, DC ;
ENGSTROM, RH .
ANESTHESIOLOGY, 1991, 74 (04) :664-669
[36]   RELATIONSHIP OF BIOIMPEDANCE TO THERMODILUTION AND ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-FUNCTION [J].
SPINALE, FG ;
SMITH, AC ;
CRAWFORD, FA .
CRITICAL CARE MEDICINE, 1990, 18 (04) :414-418
[37]  
SRAMEK BB, 1981, 5TH P INT C EL BIOIM, P39
[38]  
STETZ CW, 1982, AM REV RESPIR DIS, V126, P1001
[39]  
WEBER J, 1986, ANAESTHESIST, V35, P744
[40]   NONINVASIVE CARDIAC-OUTPUT - SIMULTANEOUS COMPARISON OF 2 DIFFERENT METHODS WITH THERMODILUTION [J].
WONG, DH ;
TREMPER, KK ;
STEMMER, EA ;
OCONNOR, D ;
WILBUR, S ;
ZACCARI, J ;
REEVES, C ;
WEIDOFF, P ;
TRUJILLO, RJ .
ANESTHESIOLOGY, 1990, 72 (05) :784-792