The Columbus Knee System: 4-Year Results of a New Deep Flexion Design Compared to the NexGen Full Flex Implant

被引:7
作者
Goebel, D. [1 ]
Schultz, W. [2 ]
机构
[1] Orthopaed Clin Donaueschingen, Karlstrabe 10, D-78166 Donaueschingen, Germany
[2] Univ Gottingen, Orthopaed Dept, D-37075 Gottingen, Germany
关键词
D O I
10.1155/2012/213817
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The Columbus knee systemis designed as a standard knee implant to allow high flexion without additional bone resection. Between August, 2004 and March, 2010 we performed 109 total knee arthroplasties of the Columbus knee system in 101 consecutive patients suffering from primary arthrosis of the knee. Mean age was 72.4 years in women and 70.3 years in men. Mean followup was 47.3 months. The 4-year results of a group of patients who received the NexGen Full Flex implant operated by the same surgeon were used for comparison. Mean total knee score was Columbus: 175.6 and NexGen Flex: 183.4; P = 0.037. Mean operation time was 53 min for Columbus and 66 min for NexGen Flex; P < 0.001. With new streamlined instruments operative time became 60 min for the Columbus; P > 0.05. Radiological assessment showed no signs of loosening for both groups. Therefore, the Columbus knee system can be recommended for flexion angles up to 140 degrees.
引用
收藏
页数:7
相关论文
共 31 条
[1]
The Kinemax total knee arthroplasty - Nine years' experience [J].
Back, DL ;
Cannon, SR ;
Hilton, A ;
Bankes, MJK ;
Briggs, TWR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03) :359-363
[2]
Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[3]
Total Knee Arthroplasty in Younger Patients: A 13-year Follow-up Study [J].
Bisschop, Roel ;
Brouwer, Reinoud W. ;
Van Raay, Jos J. A. M. .
ORTHOPEDICS, 2010, 33 (12)
[4]
Brassard MF, 2001, CLIN ORTHOP RELAT R, P26
[5]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[6]
Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Callaghan, JJ ;
O'Rourke, MR ;
Iossi, MF ;
Liu, SS ;
Goetz, DD ;
Vittetoe, DA ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1995-1998
[7]
A cost-effectiveness analysis of total hip arthroplasty for osteoarthritis of the hip [J].
Chang, RW ;
Pellissier, JM ;
Hazen, GB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 275 (11) :858-865
[8]
Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending? [J].
Cho, Sung-Do ;
Youm, Yoon-Seok ;
Park, Ki-Bong .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) :899-903
[9]
MEDICAL DEVICES Out of joint: The story of the ASR [J].
Cohen, Deborah .
BRITISH MEDICAL JOURNAL, 2011, 342
[10]
Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752