FAST SPECT SIMULATION INCLUDING OBJECT SHAPE DEPENDENT SCATTER

被引:39
作者
BEEKMAN, FJ
VIERGEVER, MA
机构
[1] Department of Radiology and Nuclear Medicine, University Hospital Utrecht, Heidelberglaan 100
基金
英国医学研究理事会;
关键词
D O I
10.1109/42.387709
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A fast simulator of SPECT projection data taking into account attenuation, distance dependent detector response, and scatter has been developed, based on an analytical point spread function model, The parameters of the scatter response are obtained from a single line source measurement with a triangular phantom, The simulator is able to include effects of object curvature on the scatter response to a high accuracy. The simulator has been evaluated for homogeneous media by measurements of Tc-99m point sources placed at different locations in a water-filled cylinder at energy windows of 15% and 20%, The asymmetrical shapes of measured projections of point sources are in excellent agreement with simulations for both energy windows, Scatter-to-primary ratio (SPR) calculations of point sources at different positions in a cylindrical phantom differ not more than a few percent from measurements, The simulator uses just a few megabytes of memory for storing the tables representing the forward model; furthermore, simulation of 60 SPECT projections from a three-dimensional digital brain phantom with 6-mm cubic voxels takes only ten minutes on a standard workstation. Therefore, the simulator could serve as a projector in iterative true 3-D SPECT reconstruction.
引用
收藏
页码:271 / 282
页数:12
相关论文
共 55 条
[41]   A PROJECTOR, BACK-PROJECTOR PAIR WHICH ACCOUNTS FOR THE 2-DIMENSIONAL DEPTH AND DISTANCE DEPENDENT BLURRING IN SPECT [J].
PENNEY, BC ;
KING, MA ;
KNESAUREK, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :681-686
[42]  
Press W.H., 1994, NUMERICAL RECIPES C, V2nd ed.
[43]  
PRETORIUS PH, 1993, J NUCL MED, V34, P330
[44]  
RAJEEVAN N, 1992, 1991 IEEE NUCL SCI S, V2, P1963
[45]  
Shepp L A, 1982, IEEE Trans Med Imaging, V1, P113, DOI 10.1109/TMI.1982.4307558
[46]   3-DIMENSIONAL PHOTON DETECTION KERNELS AND THEIR APPLICATION TO SPECT RECONSTRUCTION [J].
SMITH, MF ;
FLOYD, CE ;
JASZCZAK, RJ ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03) :605-622
[47]  
TSUI BMW, 1989, J NUCL MED, V30, P497
[48]   IMPLEMENTATION OF SIMULTANEOUS ATTENUATION AND DETECTOR RESPONSE CORRECTION IN SPECT [J].
TSUI, BMW ;
HU, HB ;
GILLAND, DR ;
GULLBERG, GT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :778-783
[49]   QUANTITATIVE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - BASICS AND CLINICAL CONSIDERATIONS [J].
TSUI, BMW ;
ZHAO, XD ;
FREY, EC ;
MCCARTNEY, WH .
SEMINARS IN NUCLEAR MEDICINE, 1994, 24 (01) :38-65
[50]   SOLID GEOMETRY BASED MODELING OF NONUNIFORM ATTENUATION AND COMPTON-SCATTERING IN OBJECTS FOR SPECT IMAGING-SYSTEMS [J].
WANG, HL ;
JASZCZAK, RJ ;
GILLAND, DR ;
GREER, KL ;
COLEMAN, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1305-1312