USE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DIODE-ARRAY DETECTION IN FORENSIC TOXICOLOGY

被引:47
作者
KOVES, EM
机构
[1] Center of Forensic Sciences, Toronto, Ont. M7A 2G8
关键词
D O I
10.1016/0021-9673(94)00840-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A comprehensive approach to the analysis for many drugs in postmortem blood and biological fluids using high-performance liquid chromatography and diode array detection has been developed. To reduce the likelihood of co-eluting interference components of postmortem blood or other drugs, selective back-extraction was also used to screen and quantitate drugs in blood and biofluids. An isocratic mobile phase (acetonitrile, phosphoric acid and triethylamine buffer, pH 3.4) was developed and found stable, reliable and convenient for general drug screening and quantitation. A library of drug spectra in the ultraviolet wavelength range (210-367 nm) was established for 272 drugs on two reversed-phase columns: Supelcosil (biphenyl) and LiChrospher RP-8. The application of several methods to whole blood, the analysis of complex cases and the use of multicomponent analysis for qualitative and quantitative analysis is discussed.
引用
收藏
页码:103 / 119
页数:17
相关论文
共 20 条
[1]   LIQUID-CHROMATOGRAPHIC INVESTIGATION OF QUINOXALINE ANTIBIOTICS AND THEIR ANALOGS BY MEANS OF ULTRAVIOLET DIODE-ARRAY DETECTION [J].
ALFREDSON, TV ;
MAKI, AH ;
ADASKAVEG, ME ;
EXCOFFIER, JL ;
WARING, MJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :277-292
[2]   AN OVERVIEW ON THE STANDARDIZATION OF CHROMATOGRAPHIC METHODS FOR SCREENING ANALYSIS IN TOXICOLOGY BY MEANS OF RETENTION INDEXES AND SECONDARY STANDARDS .2. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOGUSZ, M ;
FRANKE, JP ;
DEZEEUW, RA ;
ERKENS, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (3-4) :73-81
[3]   STANDARDIZED HPLC/DAD SYSTEM, BASED ON RETENTION INDEXES AND SPECTRAL LIBRARY, APPLICABLE FOR SYSTEMATIC TOXICOLOGICAL SCREENING [J].
BOGUSZ, M ;
WU, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (04) :188-197
[4]   COMPREHENSIVE SCREENING-PROCEDURE FOR DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, SF ;
MASSE, R ;
DUGAL, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :65-88
[5]  
DRAMMER OH, 1993, J ANAL TOXICOL, V17, P225
[6]   FASTER QUANTITATIVE-EVALUATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ULTRAVIOLET DIODE-ARRAY DATA BY MULTICOMPONENT ANALYSIS [J].
EXCOFFIER, JL ;
JOSEPH, M ;
ROBINSON, JJ ;
SHEEHAN, TL .
JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2) :15-21
[7]   HPLC PHOTODIODE ARRAY UV DETECTION FOR TOXICOLOGICAL DRUG ANALYSIS [J].
HILL, DW ;
LANGNER, KJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (2-3) :377-409
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION AND DETECTION METHODS FOR ANABOLIC COMPOUNDS [J].
JANSEN, EHJM ;
VANGINKEL, LA ;
VANDENBERG, RH ;
STEPHANY, RW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 580 (1-2) :111-124
[9]   RAPID METHOD FOR SCREENING TOXIC DRUGS IN SERUM WITH LIQUID-CHROMATOGRAPHY [J].
KABRA, PM ;
STAFFORD, BE ;
MARTON, LJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1981, 5 (04) :177-182
[10]   ASSESSMENT OF PEAK HOMOGENEITY IN LIQUID-CHROMATOGRAPHY USING MULTIVARIATE CHEMOMETRIC TECHNIQUES [J].
KELLER, HR ;
KIECHLE, P ;
ERNI, F ;
MASSART, DL ;
EXCOFFIER, JL .
JOURNAL OF CHROMATOGRAPHY, 1993, 641 (01) :1-9