QUANTITATIVE PIXE ANALYSIS USING A SCANNING PROTON MICROBEAM

被引:18
作者
JAKSIC, M [1 ]
GRIME, GW [1 ]
HENDERSON, J [1 ]
WATT, F [1 ]
机构
[1] RUDJER BOSKOVIC INST,YU-41001 ZAGREB,YUGOSLAVIA
关键词
D O I
10.1016/0168-583X(91)95397-V
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PIXE analysis is often quoted as being simple, fast, accurate and multielemental. In practice, however, especially if a wide range of samples is analysed, the measurements are adversely affected by uncertainty about the samples matrix composition, thickness and homogeneity. This is particularly true for thick samples, where major corrections to the X-ray yield can depend on knowledge of the chemical composition of the specimen. This can often be circumvented by techniques such as determination of bulk composition by other methods, or comparison with standards, but all these additional processes add to the analysis time and complexity. In addition, it is necessary to assume that the sample composition is uniform over the full area of the beam spot, not necessarily true even for carefully homogenised materials. This paper describes how the use of a scanning proton microbeam (SPM) with simultaneous PIXE, backscattered particle spectroscopy and secondary electron detection can enhance the accuracy of PIXE analysis by allowing the selection of a uniform region of the sample and the determination of the matrix composition. System calibration procedures are described and examples of analyses of standard reference materials and experimental samples are presented.
引用
收藏
页码:491 / 498
页数:8
相关论文
共 40 条
[1]   A NEW METHOD (METHOD OF ALPHA-PARAMETERS) FOR CORRECTING PIXE MEASUREMENTS FOR MATRIX EFFECTS IN INFINITELY THICK SAMPLES [J].
ALOUPOGIANNIS, P ;
WEBER, G ;
QUISEFIT, JP ;
DELBROUCK, JM ;
ROELANDTS, I ;
ROUELLE, MC ;
ROBAYE, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 42 (03) :359-368
[2]   ENERGY-LOSS EFFECT IN INNER-SHELL COULOMB IONIZATION BY HEAVY CHARGED-PARTICLES [J].
BRANDT, W ;
LAPICKI, G .
PHYSICAL REVIEW A, 1981, 23 (04) :1717-1729
[3]   THICK TARGET YIELDS FOR DETERMINATION OF THIN TARGET PIXE EFFICIENCY [J].
BUDNAR, M ;
SMIT, Z ;
KUMP, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4) :138-140
[4]   PERIPHERAL IMPERFECTIONS AND THEIR EFFECTS ON EFFICIENCY IN SI(LI) X-RAY-DETECTORS [J].
CAMPBELL, JL ;
LEIGH, RG ;
TEESDALE, WJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 5 (01) :39-43
[5]   AN INTERCOMPARISON OF SPECTRAL DATA-PROCESSING TECHNIQUES IN PIXE [J].
CAMPBELL, JL ;
MAENHAUT, W ;
BOMBELKA, E ;
CLAYTON, E ;
MALMQVIST, K ;
MAXWELL, JA ;
PALLON, J ;
VANDENHAUTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (02) :204-220
[8]   X-RAY SPECTROMETERS FOR PIXE [J].
CAMPBELL, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4) :115-125
[9]   EFFECTS OF RANDOM SURFACE-ROUGHNESS IN PIXE ANALYSIS OF THICK TARGETS [J].
CAMPBELL, JL ;
LAMB, RD ;
LEIGH, RG ;
NICKEL, BG ;
COOKSON, JA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 12 (03) :402-412
[10]  
CAMPBELL JL, 1983, NUCL INSTRUM METHODS, V216, P489