REPRODUCIBILITY OF THE INTRAVASCULAR ULTRASOUND ASSESSMENT OF STENT IMPLANTATION IN SAPHENOUS-VEIN GRAFTS

被引:36
作者
MINTZ, GS
GRIFFIN, J
CHUANG, YC
PICHARD, AD
KENT, KM
SATLER, LF
POPMA, JJ
LEON, MB
机构
[1] Intravascular Ultrasound Imaging and Cardiac Catheterization Laboratories, Washington Hospital Center, Washington, DC
关键词
D O I
10.1016/S0002-9149(99)80776-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IVUS measurements of stent and reference lumen dimensions and cross-sectional areas are highly reproducible. Furthermore, paramedical personnel can be trained to perform these measurements accurately. Thus, IVUS measurements may become the gold standard for the acute, chronic, and serial assessment of stent implantation procedures. © 1995 Excerpta Medica, Inc. All rights reserved.
引用
收藏
页码:1267 / 1270
页数:4
相关论文
共 11 条
  • [1] DIXON WJ, 1990, DMDP STATISTICAL SOF
  • [2] EbelRL, 1951, PSYCHOMETRIKA, V16, P407
  • [3] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [4] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [5] SAFETY, SUCCESS, AND RESTENOSIS AFTER ELECTIVE CORONARY IMPLANTATION OF THE PALMAZ-SCHATZ STENT IN 100 PATIENTS AT A SINGLE CENTER
    FOLEY, JB
    PENN, IM
    BROWN, RIG
    MURRAYPARSONS, N
    WHITE, J
    GALLIGAN, L
    MACDONALD, C
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (03) : 686 - 694
  • [6] QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS
    HAUDE, M
    ERBEL, R
    ISSA, H
    MEYER, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 26 - 34
  • [7] SERIAL ANGIOGRAPHIC FOLLOW-UP AFTER PALMAZ-SCHATZ STENT IMPLANTATION - COMPARISON WITH CONVENTIONAL BALLOON ANGIOPLASTY
    KIMURA, T
    NOSAKA, H
    YOKOI, H
    IWABUCHI, M
    NOBUYOSHI, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) : 1557 - 1563
  • [8] INTRAVASCULAR ULTRASONOGRAPHIC ASSESSMENT OF THE RESULTS OF CORONARY-ARTERY STENTING
    LASKEY, WK
    BRADY, ST
    KUSSMAUL, WG
    WAXLER, AR
    KROL, J
    HERRMANN, HC
    HIRSHFELD, JW
    SEHGAL, C
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (06) : 1576 - 1583
  • [9] INTRACORONARY ULTRASOUND OBSERVATIONS DURING STENT IMPLANTATION
    NAKAMURA, S
    COLOMBO, A
    GAGLIONE, A
    ALMAGOR, Y
    GOLDBERG, SL
    MAIELLO, L
    FINCI, L
    TOBIS, JM
    [J]. CIRCULATION, 1994, 89 (05) : 2026 - 2034
  • [10] INTRAVASCULAR ULTRASOUND ASSESSMENT OF BILIARY STENT IMPLANTATION IN SAPHENOUS-VEIN GRAFTS
    PAINTER, JA
    MINTZ, GS
    WONG, SC
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    SATLER, LF
    HONG, MK
    LEON, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (10) : 731 - 734