DEVELOPMENT OF CURRENT-BASED MICROSCOPIC DEFECT ANALYSIS-METHODS AND ASSOCIATED OPTICAL FILLING TECHNIQUES FOR THE INVESTIGATION ON HIGHLY IRRADIATED HIGH-RESISTIVITY SILICON DETECTORS

被引:15
作者
LI, CJ
LI, Z
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
[2] CHINESE ACAD SCI,INST SEMICOND,BEIJING 100083,PEOPLES R CHINA
关键词
D O I
10.1016/0168-9002(95)00437-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Current based microscopic defect analysis methods such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current (TSC) have been further developed in accordance with the need for the defect analysis of highly irradiated (Phi(n) > 10(13) n/cm(2)) high resistivity silicon detectors. The new I-DLTS/TSC system has a temperature range of 8 K less than or equal to T less than or equal to 450 K and a high sensitivity that can detect a defect concentration of less than 10(10)/cm(3) (background noise as low as 10 fA). A new filling method using different wavelength laser illumination has been applied, which is more efficient and suitable than the traditional voltage pulse filling. It has been found that the filling of a defect level depends on such factors as the total concentration of free carriers generated or injected, the penetration length of the laser (laser wavelength), the temperature at which the filling is taking place, as well as the decay time after the filling (but before the measurement). The mechanism of the defect filling can be explained by the competition between trapping and detrapping of defect levels, possible capture cross section temperature dependence, and interaction among various defect levels in terms of charge transferring. Optimum defect filling conditions have been suggested for highly irradiated high resistivity silicon detectors.
引用
收藏
页码:108 / 117
页数:10
相关论文
共 28 条
  • [1] THERMALLY STIMULATED CURRENT SPECTROSCOPY - EXPERIMENTAL-TECHNIQUES FOR THE INVESTIGATION OF SILICON DETECTORS
    BALDINI, A
    BRUZZI, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (04) : 932 - 936
  • [2] STUDIES OF DEEP LEVELS IN HIGH-RESISTIVITY SILICON DETECTORS IRRADIATED BY HIGH FLUENCE FAST-NEUTRONS USING A THERMALLY STIMULATED CURRENT SPECTROMETER
    BIGGERI, U
    BORCHI, E
    BRUZZI, M
    LI, Z
    LAZANU, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 964 - 970
  • [3] DEEP-LEVEL TRANSIENT SPECTROSCOPY MEASUREMENTS OF MAJORITY CARRIER TRAPS IN NEUTRON-IRRADIATED N-TYPE SILICON DETECTORS
    BORCHI, E
    BERTRAND, C
    LEROY, C
    BRUZZI, M
    FURETTA, C
    PALUDETTO, R
    RANCOITA, PG
    VISMARA, L
    GIUBELLINO, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 279 (1-2) : 277 - 280
  • [4] USING THERMALLY STIMULATED CURRENTS TO VISUALIZE DEFECT CLUSTERS IN NEUTRON-IRRADIATED SILICON
    BRUZZI, M
    BORCHI, E
    BALDINI, A
    [J]. JOURNAL OF APPLIED PHYSICS, 1992, 72 (09) : 4007 - 4013
  • [5] DETERMINATION OF THE FERMI-LEVEL POSITION FOR NEUTRON-IRRADIATED HIGH-RESISTIVITY SILICON DETECTORS AND MATERIALS USING THE TRANSIENT CHARGE TECHNIQUE (TCHT)
    EREMIN, V
    LI, Z
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) : 1907 - 1912
  • [6] EREMIN V, 1995, IN PRESS IEEE T NUCL, V42
  • [7] EREMIN V, BNL60143
  • [8] DETERMINATION OF DEEP LEVEL CENTER ENERGY AND CONCENTRATION BY THERMALLY STIMULATED CONDUCTIVITY MEASUREMENTS USING REVERSE-BIASED P-N JUNCTIONS
    FORBES, L
    SAH, CT
    [J]. SOLID-STATE ELECTRONICS, 1971, 14 (02) : 182 - &
  • [9] RADIATION EFFECTS OF DOUBLE-SIDED SILICON STRIP SENSORS
    TAMURA, N
    HATAKENAKA, T
    IWATA, Y
    KUBOTA, M
    OHSUGI, T
    OKADA, M
    UNNO, Y
    ASO, T
    ISHIZUKA, M
    MIYATA, H
    ANDO, A
    HATANAKA, K
    MIZUNO, Y
    GOTO, M
    KOBAYASHI, S
    MURAKAMI, A
    INOUE, K
    SUZUKI, Y
    DAIGO, M
    YAMAMOTO, K
    YAMAMURA, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) : 131 - 136
  • [10] TSC DEFECT LEVEL IN SILICON PRODUCED BY IRRADIATION WITH MUONS OF GEV-ENERGY
    HEIJNE, HM
    MULLER, JC
    SIFFERT, P
    [J]. RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1976, 29 (01): : 25 - 26