ONLINE CALIBRATION OF A COMPUTERIZED BIOSENSOR SYSTEM FOR CONTINUOUS MEASUREMENTS OF GLUCOSE AND LACTATE

被引:12
作者
KYROLAINEN, M [1 ]
HAKANSON, H [1 ]
MATTIASSON, B [1 ]
机构
[1] LUND UNIV,CTR CHEM,DEPT BIOTECHNOL,S-22100 LUND,SWEDEN
关键词
ONLINE CALIBRATION; CONTINUOUS MONITORING; BIOSENSOR SYSTEM; ENZYME REACTOR; GLUCOSE; LACTATE;
D O I
10.1002/bit.260450205
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An on-line calibration procedure for application in continuous monitoring systems has been developed. Control of the calibration value and recalibration on-line during monitoring is possible without having to disrupt the sample withdrawal. The calibration procedure has been applied and evaluated in a continuous biosensor system based on the detection of oxygen depletion during enzymatic substrate conversion by immobilized oxidases. Evaluation included on-line calibration during continuous measurements of glucose and lactate in bovine blood samples. Calibration of the complete system consisting of a sampling device, a sample handling step, a biocatalytic step, a detection step, and a data processing unit is performed by the on-line addition of a calibration solution to a blank sample which is fed through the system. The calibration cycle is completed within 5.5 min. When recalibration is carried out during monitoring, the calibration solution is added to the sample, instead of to a blank sample, and the increase in outlet signal is registered. The major advantage of this internal standard principle is that the calibration solution is fed through the whole system according to the same path as the sample solution and thus takes into account all parameters influencing the sample. (C) 1995 John Wiley & Sons, Inc.
引用
收藏
页码:122 / 128
页数:7
相关论文
共 20 条
[1]   ENZYME PACKED-BED SYSTEM FOR THE ONLINE MEASUREMENT OF GLUCOSE, GLUTAMATE, AND LACTATE IN BRAIN MICRODIALYSATE [J].
BOUTELLE, MG ;
FELLOWS, LK ;
COOK, C .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1790-1794
[2]   ONLINE DETERMINATION OF GLUCOSE AND LACTATE CONCENTRATIONS IN ANIMAL-CELL CULTURE BASED ON FIBER OPTIC DETECTION OF OXYGEN IN FLOW-INJECTION ANALYSIS [J].
DREMEL, BAA ;
LI, SY ;
SCHMID, RD .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (02) :133-139
[3]   COMPARISON BETWEEN DIFFERENT INORGANIC SUPPORTS FOR THE IMMOBILIZATION OF AMYLOGLUCOSIDASE AND ALPHA-AMYLASE TO BE USED IN ENZYME REACTORS IN FLOW-INJECTION SYSTEMS .1. HYDROLYSIS OF MALTOSE, MALTOOLIGOSACCHARIDES AND SOLUBLE STARCH [J].
EMNEUS, J ;
GORTON, L .
ANALYTICA CHIMICA ACTA, 1993, 276 (02) :303-318
[4]   GENERAL SAMPLING SYSTEM FOR STERILE MONITORING OF BIOLOGICAL PROCESSES [J].
HAKANSON, H ;
NILSSON, M ;
MATTIASSON, B .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :61-65
[5]   A NEEDLE-TYPE ENZYME-BASED LACTATE SENSOR FOR IN-VIVO MONITORING [J].
HU, YB ;
ZHANG, YN ;
WILSON, GS .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :503-511
[6]   BIOSENSOR MONITORING OF BLOOD LACTATE DURING OPEN-HEART-SURGERY [J].
KYROLAINEN, M ;
HAKANSON, H ;
EKROTH, R ;
MATTIASSON, B .
ANALYTICA CHIMICA ACTA, 1993, 279 (01) :149-153
[7]  
MASCINI M, 1987, CLIN CHEM, V33, P591
[8]   SAMPLING AND SAMPLE HANDLING - CRUCIAL STEPS IN PROCESS MONITORING AND CONTROL [J].
MATTIASSON, B ;
HAKANSON, H .
TRENDS IN BIOTECHNOLOGY, 1993, 11 (04) :136-142
[9]   INTEGRATION OF ENZYME-IMMOBILIZED COLUMN WITH ELECTROCHEMICAL FLOW CELL USING MICROMACHINING TECHNIQUES FOR A GLUCOSE DETECTION SYSTEM [J].
MURAKAMI, Y ;
TAKEUCHI, T ;
YOKOYAMA, K ;
TAMIYA, E ;
KARUBE, I ;
SUDA, M .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2731-2735
[10]   PROCESS MONITORING BY FLOW-INJECTION IMMUNOASSAY - EVALUATION OF A SEQUENTIAL COMPETITIVE-BINDING ASSAY [J].
NILSSON, M ;
HAKANSON, H ;
MATTIASSON, B .
JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2) :383-389