SOLID INTERFACES AS ANALYTICAL PROBLEM SOLVERS IN FLOW-INJECTION ANALYSIS

被引:7
作者
DECASTRO, MDL
TENA, MT
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba
关键词
D O I
10.1016/0039-9140(93)80139-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An overview of the advantages gained by using solid interfaces in flow injection analysis is presented. The enhancing effect on such basic analytical features as selectivity and sensitivity, diminished sample and reagent consumption, ease of automation of the preliminary steps of the analytical process and of implementation of multideterminations arising from the use of solid interfaces are discussed and illustrated by selected examples.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 169 条
[61]   SIMULTANEOUS-FLUORIMETRIC METHODS FOR THE DETERMINATION OF AMMONIA AND UREA BY USE OF FLOW-INJECTION CONFIGURATIONS WITH DUAL INJECTION VALVES [J].
IZQUIERDO, A ;
LINARES, P ;
DECASTRO, MDL ;
VALCARCEL, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (06) :490-493
[62]   DETERMINATION OF NITRATE AND NITRITE IN SEAWATER BY FLOW-INJECTION ANALYSIS [J].
JOHNSON, KS ;
PETTY, RL .
LIMNOLOGY AND OCEANOGRAPHY, 1983, 28 (06) :1260-1266
[63]   SUPPORTED LIQUID MEMBRANE TECHNIQUES FOR SAMPLE PREPARATION AND ENRICHMENT IN ENVIRONMENTAL AND BIOLOGICAL ANALYSIS [J].
JONSSON, JA ;
MATHIASSON, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (03) :106-114
[64]   THE THEORETICAL AND PRACTICAL DEVELOPMENT OF FLOW-INJECTION EXTRACTION [J].
KARLBERG, B .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :29-39
[65]   DETERMINATION OF TRACE LEVELS OF SULFATE IN WATER USING FLOW-INJECTION AND IN-LINE PRECONCENTRATION [J].
KARLSSON, M ;
PERSSON, JA ;
MOLLER, J .
ANALYTICA CHIMICA ACTA, 1991, 244 (01) :109-113
[66]   EXCHANGEABLE IMMOBILIZED ENZYME REACTOR FOR ENZYME-INHIBITION TESTS IN FLOW-INJECTION ANALYSIS USING A MAGNETIC DEVICE - DETERMINATION OF PESTICIDES IN DRINKING-WATER [J].
KINDERVATER, R ;
KUNNECKE, W ;
SCHMID, RD .
ANALYTICA CHIMICA ACTA, 1990, 234 (01) :113-117
[67]   COBALT(II)-CATALYZED CHEMILUMINESCENCE IN A DIOCTADECYLDIMETHYLAMMONIUM CHLORIDE BILAYER MEMBRANOUS MEDIUM FOR THE FLOW-INJECTION DETERMINATION OF PHENYLPYRUVIC ACID [J].
KISHIDA, M ;
MAKITA, Y ;
SUZUKI, T ;
YAMADA, M ;
HOBO, T .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2301-2305
[68]   THE APPLICATION OF STRONGLY REDUCING AGENTS IN FLOW-INJECTION ANALYSIS .6. MOLYBDENUM(III) [J].
KOK, WT ;
THUY, DT ;
NGHI, TV ;
DENBOEF, G .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :533-538
[69]   FLOW-INJECTION DONNAN DIALYSIS PRECONCENTRATION OF CATIONS FOR FLAME ATOMIC-ABSORPTION SPECTROPHOTOMETRY [J].
KOROPCHAK, JA ;
ALLEN, L .
ANALYTICAL CHEMISTRY, 1989, 61 (13) :1410-1414
[70]   GAS PERMEATION AND PRECONCENTRATION IN THE FLOW-INJECTION DETERMINATION OF ACID-AVAILABLE CYANIDE IN WASTE-WATER [J].
KUBAN, V .
ANALYTICA CHIMICA ACTA, 1992, 259 (01) :45-52