真实稳态自由进动序列成像技术的原理及应用

被引:22
作者
岳云龙
韩鸿宾
机构
[1] 北京世纪坛医院MR室
[2] 北京大学第三医院放射科
关键词
D O I
暂无
中图分类号
R445.2 [核磁共振成像];
学科分类号
100231 [临床病理学];
摘要
<正> 真实稳态自由进动序列最早由 Oppelt 等在1986年提出,由于当时技术条件的限制,不能有效地消除条带状伪影(banding artifact),使其应用受到限制。随着梯度线圈制造技术的飞速发展,切换率(slew rate)不断提高,真实稳态自由进动成像技术在诊断和功能成像中的应用逐渐增多,并且应用的范围也从原来的腹部、心脏拓展到了骨骼肌肉与神经
引用
收藏
页码:659 / 662
页数:4
相关论文
共 12 条
[1]
Quantitative assessment of patellar cartilage volume and thickness at 3.0 tesla comparing a 3D-fast low angle shot versus a 3D-true fast imaging with steady-state precession sequence for reproducibility [J].
Weckbach, S ;
Mendlik, T ;
Horger, W ;
Wagner, S ;
Reiser, MF ;
Glaser, C .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :189-197
[2]
Evaluation of lung volumetry using dynamic three-dimensional magnetic resonance imaging [J].
Plathow, C ;
Schoebinger, M ;
Fink, C ;
Ley, S ;
Puderbach, M ;
Eichinger, M ;
Bock, M ;
Meinzer, HP ;
Kauczor, HU .
INVESTIGATIVE RADIOLOGY, 2005, 40 (03) :173-179
[3]
FAIR true-FISP perfusion imaging of the kidneys [J].
Martirosian, P ;
Klose, U ;
Mader, I ;
Schick, F .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :353-361
[4]
Three-dimensional true FISP for high-resolution imaging of the whole brain [J].
Schmitz, B ;
Hagen, T ;
Reith, W .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1577-1582
[5]
Is TrueFISP a gradient-echo or a spin-echo sequence? [J].
Scheffler, K ;
Hennig, J .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) :395-397
[6]
Comparison of right ventricular volume measurement between segmented K-space gradient-echo and steady-state free precession magnetic resonance Imaging [J].
Alfakih, K ;
Thiele, H ;
Plein, S ;
Bainbridge, GJ ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (03) :253-258
[7]
Magnetic resonance tagging and echocardiographic response to dobutamine and functional improvement after reperfused myocardial infarction [J].
Kramer, CM ;
Malkowski, MJ ;
Mankad, S ;
Theobald, TM ;
Pakstis, DL ;
Rogers, WJ .
AMERICAN HEART JOURNAL, 2002, 143 (06) :1046-1051
[8]
Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation [J].
Shea, SM ;
Deshpande, VS ;
Chung, YC ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :597-602
[9]
Demonstration of periventricular brain motion during a Valsalva maneuver: description of technique, evaluation in healthy volunteers and first results in hydrocephalic patients [J].
Ertl-Wagner, BB ;
Lienemann, A ;
Reith, W ;
Rieser, MF .
EUROPEAN RADIOLOGY, 2001, 11 (10) :1998-2003
[10]
Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP [J].
Scheffler, K ;
Heid, O ;
Hennig, J .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1075-1080