Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging

被引:77
作者
Abdoli, Mehrsima [2 ]
Dierckx, Rudi A. J. O. [2 ]
Zaidi, Habib [1 ,2 ,3 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[3] Univ Geneva, Geneva Neurosci Ctr, CH-1205 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
x-ray CT; PET/CT; attenuation correction; metal artifacts; metal artifact reduction; RAY COMPUTED-TOMOGRAPHY; CONE-BEAM CT; TOTAL HIP-REPLACEMENT; HEAD-AND-NECK; STREAK ARTIFACTS; HELICAL CT; FDG PET; ITERATIVE RECONSTRUCTION; REFORMATTED PROJECTIONS; TRANSMISSION TOMOGRAPHY;
D O I
10.1118/1.4709599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Metallic implants are known to generate bright and dark streaking artifacts in x-ray computed tomography (CT) images, which in turn propagate to corresponding functional positron emission tomography (PET) images during the CT-based attenuation correction procedure commonly used on hybrid clinical PET/CT scanners. Therefore, visual artifacts and overestimation and/or underestimation of the tracer uptake in regions adjacent to metallic implants are likely to occur and as such, inaccurate quantification of the tracer uptake and potential erroneous clinical interpretation of PET images is expected. Accurate quantification of PET data requires metal artifact reduction (MAR) of the CT images prior to the application of the CT-based attenuation correction procedure. In this review, the origins of metallic artifacts and their impact on clinical PET/CT imaging are discussed. Moreover, a brief overview of proposed MAR methods and their advantages and drawbacks is presented. Although most of the presented MAR methods are mainly developed for diagnostic CT imaging, their potential application in PET/CT imaging is highlighted. The challenges associated with comparative evaluation of these methods in a clinical environment in the absence of a gold standard are also discussed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4709599]
引用
收藏
页码:3343 / 3360
页数:18
相关论文
共 141 条
[1]
Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid [J].
Abdoli, Mehrsima ;
de Jong, Johan R. ;
Pruim, Jan ;
Dierckx, Rudi A. J. O. ;
Zaidi, Habib .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (12) :2257-2268
[2]
Reduction of dental filling metallic artifacts in CT-based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm [J].
Abdoli, Mehrsima ;
Ay, Mohammad Reza ;
Ahmadian, Alireza ;
Dierckx, Rudi A. J. O. ;
Zaidi, Habib .
MEDICAL PHYSICS, 2010, 37 (12) :6166-6177
[3]
A virtual sinogram method to reduce dental metallic implant artefacts in computed tomography-based attenuation correction for PET [J].
Abdoli, Mehrsima ;
Ay, Mohammad Reza ;
Ahmadian, Alireza ;
Zaidi, Habib .
NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (01) :22-31
[4]
PET/CT scanner instrumentation, challenges, and solutions [J].
Alessio, AM ;
Kinahan, PE ;
Cheng, PM ;
Vesselle, H ;
Karp, JS .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (06) :1017-+
[5]
[Anonymous], THESIS KATHOLIEKE U
[6]
Penalized-Likelihood Reconstruction for Metal Artifact Reduction in Cone-Beam CT [J].
Aootaphao, Sorapong ;
Pintavirooj, Chuchart ;
Sotthivirat, Saowapak .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :2733-2736
[7]
Qualitative and Quantitative Assessment of Metal Artifacts Arising from Implantable Cardiac Pacing Devices in Oncological PET/CT Studies: A Phantom Study [J].
Ay, Mohammad R. ;
Mehranian, Abolfazl ;
Abdoli, Mehrsima ;
Ghafarian, Pardis ;
Zaidi, Habib .
MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (06) :1077-1087
[8]
Bai CY, 2003, J NUCL MED, V44, P1855
[9]
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering [J].
Bal, Matthieu ;
Spies, Lothar .
MEDICAL PHYSICS, 2006, 33 (08) :2852-2859
[10]
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429