Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning

被引:73
作者
Chetty, Indrin J. [1 ]
Rosu, Mihaela [1 ]
Kessler, Marc L. [1 ]
Fraass, Benedick A. [1 ]
Ten Haken, Randall K. [1 ]
Kong, Feng-Ming [1 ]
McShan, Daniel L. [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 04期
关键词
Monte Carlo; based treatment planning; statistical uncertainties; dose distributions; uncertainty volume histograms; lung cancer; DOSE-VOLUME HISTOGRAMS; PHOTON; CODE; PROBABILITY; PLANS; DPM;
D O I
10.1016/j.ijrobp.2006.03.039
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate methods of reporting and analyzing statistical uncertainties in doses to targets and normal tissues in Monte Carlo (MC)-based treatment planning. Methods and Materials: Methods for quantifying statistical uncertainties in dose, such as uncertainty specification to specific dose points, or to volume-based regions, were analyzed in MC-based treatment planning for 5 lung cancer patients. The effect of statistical uncertainties on target and normal tissue dose indices was evaluated. The concept of uncertainty volume histograms for targets and organs at risk was examined, along with its utility, in conjunction with dose volume histograms, in assessing the acceptability of the statistical precision in dose distributions. The uncertainty evaluation tools were extended to four-dimensional planning for application on multiple instances of the patient geometry. All calculations were performed using the Dose Planning Method MC code. Results: For targets, generalized equivalent uniform doses and mean target doses converged at 150 million simulated histories, corresponding to relative uncertainties of less than 2% in the mean target doses. For the normal lung tissue (a volume-effect organ), mean lung dose and normal tissue complication probability converged at 150 million histories despite the large range in the relative organ uncertainty volume histograms. For "serial" normal tissues such as the spinal cord, large fluctuations exist in point dose relative uncertainties. Conclusions: The tools presented here provide useful means for evaluating statistical precision in MC-based dose distributions. Tradeoffs between uncertainties in doses to targets, volume-effect organs, and "serial" normal tissues must be considered carefully in determining acceptable levels of statistical precision in MC-computed dose distributions. (c) 2006 Elsevier Inc.
引用
收藏
页码:1249 / 1259
页数:11
相关论文
共 30 条
[1]   Monte Carlo dose calculations and radiobiological modelling: analysis of the effect of the statistical noise of the dose distribution on the probability of tumour control [J].
Buffa, FM ;
Nahum, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :3009-3023
[2]   A virtual source model for Monte Carlo modeling of arbitrary intensity distributions [J].
Chetty, I ;
DeMarco, JJ ;
Solberg, TD .
MEDICAL PHYSICS, 2000, 27 (01) :166-172
[3]   Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media [J].
Chetty, IJ ;
Charland, PM ;
Tyagi, N ;
McShan, DL ;
Fraass, BA ;
Bielajew, AF .
MEDICAL PHYSICS, 2003, 30 (04) :563-573
[4]  
CHETTY IJ, 2006, IN PRESS MED PHYS
[5]  
CHETTY IJ, 2004, P 14 ICCR, P457
[6]   Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning [J].
Cygler, JE ;
Daskalov, GM ;
Chan, GH ;
Ding, GX .
MEDICAL PHYSICS, 2004, 31 (01) :142-153
[7]  
FRAASS BA, 2003, INT J RADIAT ONCOL, V57, P37
[8]   The effect of statistical uncertainty on inverse treatment planning based on Monte Carlo dose calculation [J].
Jeraj, R ;
Keall, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3601-3613
[9]   Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculations [J].
Jiang, SB ;
Pawlicki, T ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2151-2161
[10]   Investigation of variance reduction techniques for Monte Carlo photon dose calculation using XVMC [J].