Monitoring of low concentrations of glucose in fermentation broth

被引:14
作者
Nandakumar, MP
Sapre, A
Lali, A
Mattiasson, B
机构
[1] Univ Lund, Dept Biotechnol, Ctr Chem & Chem Engn, SE-22100 Lund, Sweden
[2] Univ Mumbai, Dept Chem Technol, Div Chem Engn, Bombay 400019, Maharashtra, India
关键词
D O I
10.1007/s002530051552
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A highly sensitive glucose sensor, operating in flow-injection analysis (FIA) mode, was developed for the detection of glucose in fermentation broth. The assay system is based upon the post-column reaction of the peroxide formed in the glucose-oxidase-catalysed reaction and subsequent spectrophotometric detection of the coloured product formed. The sensor system was characterised and calibrated using standard solutions, and later used for quantification of glucose in fermentation media. Two types of enzyme column were used: one operated in packed-bed mode and the other in expanded-bed mode. Both columns were integrated into a FIA system and were found to give good analytical results. Glucose concentrations as low as 0.1 mg/l and 5 mg/l could be detected in packed- and expanded-bed modes respectively. Glucose concentrations were measured during typical fed-batch fermentation conditions in this system, and the results are presented.
引用
收藏
页码:502 / 507
页数:6
相关论文
共 19 条
[1]   SEQUENTIAL ENZYMATIC MONITORING OF GLUCOSE, ETHANOL AND GLUTAMATE IN BIOREACTOR FERMENTATION BROTH CONTAINING A HIGH-SALT CONCENTRATION BY A MULTICHANNEL FLOW-INJECTION ANALYSIS METHOD [J].
CHEN, RLC ;
MATSUMOTO, K .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :145-151
[2]   On-line glucose monitoring by using microdialysis sampling and amperometric detection based on 'wired' glucose oxidase in carbon paste [J].
Csoregi, E ;
Laurell, T ;
Katakis, I ;
Heller, A ;
Gorton, L .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :31-40
[3]   DETERMINATION OF PEROXIDE BY AUTOMATIC COLORIMETRY [J].
DUKES, EK ;
HYDER, ML .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1689-&
[4]  
HOLME T, 1970, Process Biochemistry, V5, P62
[5]  
HOLST O, 1988, APPL MICROBIOL BIOT, V28, P32
[6]   Characterization and application of an on-line flow injection analysis wall-jet electrode system for glucose monitoring during fermentation [J].
Huang, YL ;
Foellmer, TJ ;
Ang, KC ;
Khoo, SB ;
Yap, MGS .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :223-232
[7]   ONLINE DETERMINATION OF GLUCOSE-CONCENTRATION THROUGHOUT ANIMAL-CELL CULTURES BASED ON CHEMILUMINESCENT DETECTION OF HYDROGEN-PEROXIDE COUPLED WITH FLOW-INJECTION ANALYSIS [J].
HUANG, YL ;
LI, SY ;
DREMEL, BAA ;
BILITEWSKI, U ;
SCHMID, RD .
JOURNAL OF BIOTECHNOLOGY, 1991, 18 (1-2) :161-172
[8]   APPLICATION OF ENZYME-FIELD EFFECT TRANSISTOR SENSOR ARRAYS AS DETECTORS IN A FLOW-INJECTION ANALYSIS SYSTEM FOR SIMULTANEOUS MONITORING OF MEDIUM COMPONENTS .2. MONITORING OF CULTIVATION PROCESSES [J].
KULLICK, T ;
BECK, U ;
SCHUBERT, J ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :25-31
[9]   ONLINE CALIBRATION OF A COMPUTERIZED BIOSENSOR SYSTEM FOR CONTINUOUS MEASUREMENTS OF GLUCOSE AND LACTATE [J].
KYROLAINEN, M ;
HAKANSON, H ;
MATTIASSON, B .
BIOTECHNOLOGY AND BIOENGINEERING, 1995, 45 (02) :122-128
[10]   SAMPLING AND SAMPLE HANDLING - CRUCIAL STEPS IN PROCESS MONITORING AND CONTROL [J].
MATTIASSON, B ;
HAKANSON, H .
TRENDS IN BIOTECHNOLOGY, 1993, 11 (04) :136-142